3.2 Nominal data

Motor

M3G055-CF

Phase

1~

Nominal voltage in VAC

230

Frequency in Hz

50/60

Type of data definition

ml

Speed in min

-1

2670

Power input in W

105

Current draw in A

0.78

Min. ambient
temperature in °C

-25

Max. ambient
temperature in °C

60

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical description

Mass

1.8 kg

Size

220 mm

Surface of rotor

Thick layer passivated

Material of electronics
housing

Die-cast aluminium

Material of impeller

Plastic PA6, fibreglass-reinforced

Housing material

Plastic PA6, fibreglass-reinforced

Number of blades

11

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44

Insulation class

"B"

Humidity class

F3-1

Mounting position

any

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Technical features

- Control input 0-10 VDC / PWM
- Output 10 VDC, max. 1.1 mA
- Tach output
- Motor current limit
- Soft start

Leakage current

<= 3.5 mA

Motor protection

Reverse polarity and locked-rotor
protection

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Graphic rendition of products

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

3.6 Electromagnetic compatibility

EMC interference
immunity

Acc. to EN 61000-6-2 (industrial
environment)

EMC interference
emission

Acc. to EN 61000-6-3 (household
environment)

EMC harmonics

Acc. to EN 61000-3-2/3

Item no.: 50701-5-9970 · Revision: 74083 · Print-out: 2012-02-17 · Y. Uhlmann (VM-TDO) · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание K3G220-CD17-01

Страница 1: ...sonnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the d...

Страница 2: ...is EMC compliant 1 7 Mechanical movement DANGER Rotating device Body parts coming into contact with the rotor and impeller can be injured Secure the device against accidental contact Before working o...

Страница 3: ...owing ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highly corros...

Страница 4: ...ve the unit mm 1 Connection line H03VV F3G0 5 3 x brass lead tips crimped 2 Connection line A03VV F4x0 25 4 x brass lead tips crimped Item no 50701 5 9970 Revision 74083 Print out 2012 02 17 Y Uhlmann...

Страница 5: ...ion Reverse polarity and locked rotor protection Cable exit Variable Protection class I if protective earth is connected by customer Product conforming to standard EN 60335 1 CE For cyclic speed loads...

Страница 6: ...requisites Check whether the data on the type plate agree with the connection data Before connecting the device ensure that the supply voltage matches the operating voltage of the device Only use cabl...

Страница 7: ...ellow Control input 0 10 V or PWM electrically isolated 5 Tacho white Tach output Open Collector 1 pulse per revolution electrically isolated 6 10V max 1 1 mA red Voltage output 10V 1 1mA electrically...

Страница 8: ...h on the device via the control input Do not switch the motor e g in cyclic operation on and off via power supply Switching off the device for maintenance work Switch on the device via the control inp...

Страница 9: ...ect connection see connection diagram Overtemperature of electronics motor Insufficient cooling Improve cooling Let the device cool down To reset the error message switch off the mains supply voltage...

Страница 10: ...mpeller Condensate discharge holes for clogging as necessary Visual inspection At least every 6 months Open bore holes Check the ball bearings to ensure they are quiet can move easily and are free of...

Страница 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information ebm papst K3G220 CD17 01...