ebm-papst K3G200-BDA4-04 Скачать руководство пользователя страница 5

Operating instructions

K3G200-BDA4-04

Translation of the original operating instructions

3.2 Nominal data

Motor

M3G074-CF

Nominal voltage / VDC

48

Nominal voltage
range / VDC

36 .. 57

Type of data definition

fa

State

prelim.

Speed (rpm) / min

-1

5050

Power input / W

320

Current draw / A

6.7

Max. back pressure / Pa

750

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

50

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data in accordance with ecodesign regulation EU 327/
2011

Actual

Request 2015

01 Overall efficiency η

es

/ %

47.5

34.6

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

62.9

50

05 Variable speed drive

Yes

06 Year of manufacture

The year of manufacture is specified on the
rating plate on the product.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
County court Stuttgart · HRA 590344
D-74673 Mulfingen

08 Type

K3G200-BDA4-04

09 Power input P

e

/ kW

0.34

09 Air flow q

v

/ m³/h

800

09 Pressure increase total p

sf

/

Pa

660

10 Speed (rpm) n / min

-1

4915

11 Specific ratio

*

1.01

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data definition with optimum efficiency. The ErP data is determined using a motor-impeller

combination in a standardised measurement configuration.

3.4 Technical features

Mass

2.26 kg

Size

200 mm

Surface of rotor

Coated in black

Material of impeller

PA plastic

Housing material

PA plastic

Material of support
bracket

PA plastic

Number of blades

7

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position

Insulation class

"B"

Humidity (F)/
environmental
protection class (H)

F2-1

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Technical features

- Tach output
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM
- Over-temperature protected electronics

Motor protection

Reverse polarity and locked-rotor
protection

Cable exit

Lateral

Product conforming
to standard

EN 60335-1

Approval

CCC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

Notes on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may vary during the production period.
Strength, dimensional stability and dimensional accuracy are not affected
by this.
The colour pigments of the paints used react perceptibly to UV light over
the course of time. This does not however have any influence on the
technical properties of the products. To prevent the formation of patches
and fading, the product is to be protected against UV radiation. Changes
in colour are not a reason for complaint and are not covered by the
warranty.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

Item no. 50969-5-9970 · ENG · Revision 89188 · Release 2016-04-18 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание K3G200-BDA4-04

Страница 1: ...re permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the devic...

Страница 2: ...er can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair dangling items of c...

Страница 3: ...mproper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Resonance mode operation...

Страница 4: ...res have the unit mm 1 Connection line PVC AWG16 4x crimped core end sleeves 2 Direction of air flow V 3 Mounting dimensions Item no 50969 5 9970 ENG Revision 89188 Release 2016 04 18 Page 4 9 ebm pap...

Страница 5: ...plastic Housing material PA plastic Material of support bracket PA plastic Number of blades 7 Direction of rotation Clockwise seen on rotor Type of protection IP 44 Depending on installation and posit...

Страница 6: ...off with an all pole separating switch When working on the fan you must switch off the installation machine in which the fan is installed and secure it from being switched on again NOTE Water penetra...

Страница 7: ...ly 48 VDC residual ripple 3 5 2 0 10 VDC yellow Control input Re 100 K 3 Tach white Speed monitoring output 3 pulses per revolution Isink max 10 mA 4 GND blue Reference mass Item no 50969 5 9970 ENG R...

Страница 8: ...a the control input Do not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the supply voltage 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do...

Страница 9: ...specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassem...

Отзывы: