Operating instructions
K3G200-AD11-02
Translation of the original operating instructions
4.4 Connection diagram
Drawing preliminary!
No.
Conn.
Designation
Color
Function/assignment
CON10 L
black
Power supply 115 VAC, 50-60 Hz, see nameplate for voltage range
CON11 N
blue
Neutral conductor
CON12 PE
green/
yellow
Protective earth
1
GND
blue
GND connection for control interface
2
0- 10V PWM
yellow
Control input 0-10 V or PWM, electrically isolated
3
10V/ max 1.1mA
red
Voltage output 10 VDC 1.1 mA, electrically isolated, short-circuit-proof
4
Tach
white
Tach output: Open collector, 1 pulse per revolution, electrically isolated, Isink max = 10 mA
Item no. 55098-5-9970 · ENU · Change 240882 · Approved 2021-09-09 · Page 9 / 12