ebm-papst K1G220-AF92-02 Скачать руководство пользователя страница 7

Operating instructions

K1G220-AF92-02

Translation of the original operating instructions

Fig. 2: Cable routing for fans installed upright. The cables must always
be routed downward.

NOTE

Cable routing is to be performed accordingly if use is made of
the ESM plug-in module to connect the fan.

Item no. 50766-5-9970 · ENU · Change 234164 · Approved 2021-07-14 · Page 7 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание K1G220-AF92-02

Страница 1: ...nd authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Ba...

Страница 2: ...y that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accide...

Страница 3: ...Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the cu...

Страница 4: ...TECHNICAL DATA 3 1 Product drawing All dimensions in mm 1 Cable AWG20 3x splice Item no 50766 5 9970 ENU Change 234164 Approved 2021 07 14 Page 4 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673...

Страница 5: ...nsult ebm papst for support Use the device in accordance with its degree of protection Information on surface quality The surfaces of the products conform to the generally applicable industrial standa...

Страница 6: ...fan secure the system machine in which the fan is installed so as to prevent it from being switched back on NOTE Water ingress into wires or cables Water ingress at the customer end of the cable can d...

Страница 7: ...st always be routed downward NOTE Cable routing is to be performed accordingly if use is made of the ESM plug in module to connect the fan Item no 50766 5 9970 ENU Change 234164 Approved 2021 07 14 Pa...

Страница 8: ...lue Neutral conductor 2 L black Power supply 230 VAC 50 60 Hz see nameplate for voltage range 3 S brown Speed selection switch open speed 1 fast switch closed speed 2 slow Item no 50766 5 9970 ENU Cha...

Страница 9: ...rotective functions cause the motor to switch off automatically in the event of the faults described in the table Fault Safety feature description function Rotor position detection error An automatic...

Страница 10: ...iminate vibrations the fan may need to be rebalanced To have it rebalanced contact ebm papst The fan is equipped with maintenance free ball bearings The lifetime lubrication of the ball bearings is de...

Страница 11: ...tallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plasti...