ebm-papst K1G190-AD73-02 Скачать руководство пользователя страница 8

Operating instructions

K1G190-AD73-02

Translation of the original operating instructions

4.4 Connection diagram

Drawing preliminary!

No.

Conn.

Designation

Color

Function/assignment

1

N

blue

Neutral conductor

2

L

black

Power supply 230 VAC, 50-60 Hz, see nameplate for voltage range

3

S

brown

Speed selection: switch open speed 1 (fast), switch closed speed 2 (slow)

Item no. 50762-5-9970 · ENU · Change 236880 · Approved 2021-10-15 · Page 8 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание K1G190-AD73-02

Страница 1: ...nd authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Ba...

Страница 2: ...y that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accide...

Страница 3: ...Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the cu...

Страница 4: ...NICAL DATA 3 1 Product drawing All dimensions in mm 1 Cable AWG20 3x crimped splices Item no 50762 5 9970 ENU Change 236880 Approved 2021 10 15 Page 4 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 7...

Страница 5: ...77 With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use th...

Страница 6: ...ched off with an all pole disconnection switch When working on the fan secure the system machine in which the fan is installed so as to prevent it from being switched back on NOTE Water ingress into w...

Страница 7: ...e cables must always be routed downward NOTE Cable routing is to be performed accordingly if use is made of the ESM plug in module to connect the fan Item no 50762 5 9970 ENU Change 236880 Approved 20...

Страница 8: ...lue Neutral conductor 2 L black Power supply 230 VAC 50 60 Hz see nameplate for voltage range 3 S brown Speed selection switch open speed 1 fast switch closed speed 2 slow Item no 50762 5 9970 ENU Cha...

Страница 9: ...rotective functions cause the motor to switch off automatically in the event of the faults described in the table Fault Safety feature description function Rotor position detection error An automatic...

Страница 10: ...iminate vibrations the fan may need to be rebalanced To have it rebalanced contact ebm papst The fan is equipped with maintenance free ball bearings The lifetime lubrication of the ball bearings is de...

Страница 11: ...tallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plasti...

Отзывы: