Operating instructions
G3G146-CC11-14
Translation of the original operating instructions
4.4 Connection screen
Line
No.
Signal
Colour
Function / assignment
2
L
brown
Power supply 230 VAC, 50-60 Hz, see type plate for voltage range
3
N
blue
Neutral conductor
1
PE
green/
yellow
Protective earth
7
0-10 V PWM
yellow
Control input 0 - 10 V or PWM, electrically isolated
5
Tach
white
Tach output: Open Collector, 1 pulse per revolution, electrically isolated
6
10V
red
max. 1.1 mA, voltage output 10 V/1.1 mA, electrically isolated, not short-circuit-proof
4
GND
blue
GND - Connection for control interface
Item no. 50245-5-9970 · Revision 75643 · Release 2011-11-24 · Page 7 / 10