Operating instructions
G3G120-BC25-01
Translation of the original operating instructions
3.2 Nominal data
Motor
M3G055-BD
Phase
1~
Nominal voltage / VAC
230
Nominal voltage
range / VAC
200 .. 240
Frequency / Hz
50/60
Method of obtaining
data
ml
Speed (rpm) / min
-1
2770
Power consumption / W
84
Current draw / A
0.7
Min. back pressure / Pa
0
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
60
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Technical description
Weight
1.7 kg
Size
120 mm
Motor size
55
Rotor surface
Unpainted
Impeller material
Sheet steel, galvanized
Housing material
Die-cast aluminum
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP54
Insulation class
"B"
Moisture (F) /
Environmental (H)
protection class
H1
Installation position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensation
drainage holes
None, open rotor
Mode
S1
Motor bearing
Ball bearing
Technical features
- Output 10 VDC, max. 1.1 mA
- Tach output
- Motor current limitation
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from supply
- Thermal overload protection for motor
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
<= 3.5 mA
Motor protection
Electronic motor protection
with cable
Variable
Protection class
I (with customer connection of protective
earth)
Conformity with
standards
CE
Approval
CCC
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
;
Use the device in accordance with its degree of protection.
Information on surface quality
The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.
3.4 Mounting data
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
For screw clearance, see Chapter 3.1 Product drawing
Strength class of
screws
8.8
Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.
3.5 Transport and storage conditions
Max. permitted
ambient temp. for
motor (transport/
storage)
+ 80 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
- 40 °C
3.6 Electromagnetic compatibility
EMC immunity to
interference
According to EN 61000-6-2 (industrial
environment)
EMC circuit feedback
According to EN 61000-3-2/3
EMC interference
emission
According to EN 55022 (class B,
household environment), the application
may require ferritic damping in the cable
due to the conditions of installation.
Item no. 51486-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 5 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com