Operating instructions
G3G120-BB03-02
Translation of the original operating instructions
3.2 Nominal data
Motor
M3G055-BD
Phase
1~
Nominal voltage / VAC
230
Frequency / Hz
50/60
Method of obtaining
data
fa
Speed / min
-1
2200
Power consumption / W
41
Current draw / A
0.3
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
60
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Technical description
Weight
1.9 kg
Fan size
120 mm
Rotor surface
Galvanized
Electronics housing
material
Die-cast aluminum
Impeller material
Sheet steel, galvanized
Housing material
Die-cast aluminum
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP44
Insulation class
"B"
Moisture (F) /
Environmental (H)
protection class
F3-1
Installation position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensation
drainage holes
On rotor side
Mode
S1
Motor bearing
Ball bearing
Technical features
- Output 10 VDC, max. 1.1 mA
- Tach output
- Motor current limitation
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from supply
- Thermal overload protection for motor
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
<= 3.5 mA
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Variable
Protection class
I (with customer connection of protective
earth)
Conformity with
standards
EN 60335-1; CE
Approval
EAC
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
3.4 Mounting data
For screw clearance, see Chapter 3.1 Product drawing
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Strength class of
screws
8.8
Any further mounting data required can be taken from the product drawing.
3.5 Transport and storage conditions
;
Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
+ 80 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
- 40 °C
3.6 Electromagnetic compatibility
EMC immunity to
interference
According to EN 61000-6-2 (industrial
environment)
EMC circuit feedback
According to EN 61000-3-2/3
EMC interference
emission
According to EN 61000-6-3 (household
environment)