ebm-papst G2E180-EH03-01 Скачать руководство пользователя страница 5

Operating instructions

G2E180-EH03-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M2E074-EI

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

fa

ml

Valid for approval /
standard

CE

CE

Speed (rpm) / min

-1

1950

2150

Power input / W

400

415

Current draw / A

1.75

1.82

Motor capacitor / µF

8

8

Capacitor voltage / VDB

400

400

Capacitor standard

S0 (CE)

S0 (CE)

Min. back pressure / Pa

0

250

Min. ambient
temperature / °C

-25

-25

Max. ambient
temperature / °C

40

30

Starting current / A

2.2

2

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data in accordance with ecodesign regulation EU 327/
2011

Actual

Request 2015

01 Overall efficiency η

es

/ %

35.3

33.7

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

45.6

44

05 Variable speed drive

No

06 Year of manufacture

The year of manufacture is specified on the
rating plate on the product.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
County court Stuttgart · HRA 590344
D-74673 Mulfingen

08 Type

G2E180-EH03-01

09 Power input P

e

/ kW

0.23

09 Air flow q

v

/ m³/h

460

09 Pressure increase total p

fs

/

Pa

653

10 Speed (rpm) n / min

-1

2680

11 Specific ratio

*

1.01

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data definition with optimum efficiency. The ErP data is determined using a motor-impeller

combination in a standardised measurement configuration.

3.4 Technical features

Mass

5.3 kg

Size

180 mm

Motor size

74

Surface of rotor

Coated in black

Material of impeller

Sheet steel, coated in black

Housing material

Die-cast aluminium

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP44; Depending on installation and
position as per EN 60034-5

Insulation class

"B"

Humidity (F) /
environmental
protection class (H)

H0 - dry environment

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensation
drainage holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

CCC; EAC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

;

Use the device in accordance with its protection type.

Notes on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may vary during the production period.
Strength, dimensional stability and dimensional accuracy are not affected
by this.
The colour pigments of the paints used react perceptibly to UV light over
the course of time. To prevent the formation of patches and fading, the
product is to be protected against UV radiation. Changes in colour are
not a reason for complaint and are not covered by the warranty. UV
radiation in the frequency range and the intensity of natural solar radiation
has no effect on the technical properties of the products.

3.5 Mounting data

Any further mounting data required can be taken from the product
drawing or Section chapter 4.1 Connecting the mechanical system.

Strength class for
mounting screws

8.8

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Item no. 10294-5-9970 · ENG · Revision 212114 · Release 2020-03-10 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание G2E180-EH03-01

Страница 1: ...horised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards st...

Страница 2: ...customer s side Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the dev...

Страница 3: ...evice with an imbalance e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted from the customer system to the fan Opera...

Страница 4: ...All measures have the unit mm 1 Connection line PVC 4G 0 5 mm 4x lead tips crimped 2 For self tapping M4 screws Item no 10294 5 9970 ENG Revision 212114 Release 2020 03 10 Page 4 11 ebm papst Mulfing...

Страница 5: ...Housing material Die cast aluminium Direction of rotation Clockwise seen on rotor Type of protection IP44 Depending on installation and position as per EN 60034 5 Insulation class B Humidity F environ...

Страница 6: ...CAUTION Electrical voltage The device is a built in component and features no electrically isolating switch Connect the device only to circuits that can be switched off using an all pole disconnectin...

Страница 7: ...all pole sine filter protects the motor against high voltage transients that can destroy the winding insulation system and against harmful bearing currents Heating up of the motor when using a frequen...

Страница 8: ...ctions 4 4 Connection screen U1 blue Z brown U2 black PE green yellow Item no 10294 5 9970 ENG Revision 212114 Release 2020 03 10 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen...

Страница 9: ...MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Return the device to ebm papst for repair or replacement WARNING Terminals and connections have voltage even with a...

Страница 10: ...tact for damage and to ensure that it is intact Visual inspection At least every 6 months Repair or replacement of the device Check the device for damage to blades and housing Visual inspection At lea...

Страница 11: ...external rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magnets can be disposed of in the same way as normal iron and steel Electrical insulating materials on the product in cables and wires...

Отзывы: