ebm-papst G2E160-BY47-02 Скачать руководство пользователя страница 5

Operating instructions

G2E160-BY47-02

Translation of the original operating instructions

3.2 Nominal data

Motor

M2E068-EC

Phase

1~

1~

1~

Nominal voltage / VAC

230

230

230

Frequency / Hz

50

60

60

Type of data definition

fa

ml

ml

Valid for approval /
standard

CE

CE

UL

Speed / min

-1

2100

2100

2100

Power input / W

240

280

310

Current draw / A

1.05

1.23

1.3

Motor capacitor / µF

6

6

6

Capacitor voltage / VDB

400

400

400

Min. back pressure / Pa

0

50

50

Min. ambient
temperature / °C

-25

-25

-25

Max. ambient
temperature / °C

50

30

30

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.01

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

26.8

25.6

32.6

Efficiency grade N

38.2

37

44

Power input P

e

/ kW

0.16

Air flow q

v

/ m³/h

365

Pressure increase total p

sf

/ Pa

440

Speed n / min

-1

2590

Data established at point of optimum efficiency

3.4 Technical features

Mass

4.08 kg

Size

160 mm

Material of impeller

Sheet steel, galvanised

Housing material

Die-cast aluminium

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position

Insulation class

"B"

Humidity class

F0

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

CCC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 12186-5-9970 · Revision 76115 · Release 2012-02-16 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание G2E160-BY47-02

Страница 1: ...m Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety...

Страница 2: ...could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNI...

Страница 3: ...the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highl...

Страница 4: ...Product drawing All measures have the unit mm 1 Connection line PVC 4G 0 5mm 4x brass lead tips crimped Item no 12186 5 9970 Revision 76115 Release 2012 02 16 Page 4 9 ebm papst Mulfingen GmbH Co KG B...

Страница 5: ...nter clockwise seen on rotor Type of protection IP 44 Depending on installation and position Insulation class B Humidity class F0 Mounting position Any Condensate discharge holes None Operation mode S...

Страница 6: ...cted in a dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check whether the data on the type plate agree with th...

Страница 7: ...tructions 4 4 Connection screen U1 blue Z brown U2 black PE green yellow Item no 12186 5 9970 Revision 76115 Release 2012 02 16 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Ph...

Страница 8: ...off Electric shock risk of injury Discharge the capacitors before working on the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Danger of...

Страница 9: ...t it is intact Visual inspection At least every 6 months Repair or replacement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of...

Отзывы: