Operating instructions
G2E140-NL33-01
Translation of the original operating instructions
3.2 Nominal data
Motor
M2E068-CF
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
fa
ml
Valid for approval /
standard
CE
CE
Speed / min
-1
2000
2150
Power input / W
137
155
Current draw / A
0.6
0.68
Motor capacitor / µF
3
3
Capacitor voltage / VDB
400
400
Capacitor standard
P0 (CE)
P0 (CE)
Min. back pressure / Pa
0
130
Max. ambient
temperature / °C
50
40
Starting current / A
1.18
1.1
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Technical features
Mass
2.09 kg
Size
140 mm
Surface of rotor
Partially cast in aluminium
Material of impeller
PP-TV40 plastic
Housing material
Heat-resistant plastic
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 44; Depending on installation and
position
Insulation class
"B"
Humidity class
F0
Mounting position
Any
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired
internally
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1; CE
Approval
GOST
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
;
Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
;
Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 11038-5-9970 · Revision 75318 · Release 2011-10-10 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com