ebm-papst G2D140-AC38-03 Скачать руководство пользователя страница 5

Operating instructions

G2D140-AC38-03

Translation of the original operating instructions

3.2 Nominal data

Motor

M2D068-DF

Phase

3~

3~

3~

3~

Nominal voltage / VAC

400

400

400

400

Wiring

Δ

Y

Δ

Y

Frequency / Hz

50

50

60

60

Method of obtaining
data

fa

fa

fa

fa

Valid for approval/
standard

CE

CE

CE

CE

Speed (rpm) / min

-1

2300

1600

2350

1500

Power consumption / W

145

80

190

90

Current draw / A

0.22

0.13

0.29

0.14

Min. ambient
temperature / °C

-40

-40

-40

-40

Max. ambient
temperature / °C

80

80

80

80

Starting current / A

0.55

0.19

0.5

0.18

Phase

3~

3~

Nominal voltage / VAC

480

480

Wiring

Δ

Y

Frequency / Hz

60

60

Method of obtaining
data

fa

fa

Valid for approval/
standard

CE

CE

Speed (rpm) / min

-1

2650

1750

Power consumption / W

225

120

Current draw / A

0.29

0.15

Min. ambient
temperature / °C

-40

-40

Max. ambient
temperature / °C

80

80

Starting current / A

0.65

0.22

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

3.5 kg

Size

140 mm

Motor size

68

Rotor surface

Painted black

Impeller material

Sheet steel, galvanized

Housing material

Die-cast aluminum

Guard grille material

Hot-dip galvanized and spot-welded net

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP44; installation- and position-dependent
as per EN 60034-5

Insulation class

"F"

Moisture (F) /
Environmental (H)
protection class

H1+

Installation position

Any

Condensation
drainage holes

On rotor side

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) with
basic insulation

with cable

Axial

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 45545-2 + A1:2015; EN 50155:
2008; EN 61373, Cat. 1B: 2010

Approval

EAC

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. The product is to be protected against UV radiation to
prevent the formation of patches and fading. Changes in color are not a
reason for complaint and are not covered by the warranty. UV radiation
in the frequency range and the intensity of natural solar radiation has no
effect on the technical properties of the products.

3.4 Mounting data

Further mounting data can be taken from the product drawing or Chapter
4.1 Mechanical connection as required.

Strength class of
screws

8.8

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

-40 °C

Item no. 16623-5-9970 · ENU · Change 257119 · Approved 2023-02-03 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание G2D140-AC38-03

Страница 1: ...ansported unpacked installed operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carr...

Страница 2: ...l movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait...

Страница 3: ...following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also i...

Страница 4: ...uct drawing All dimensions in mm 1 Cable halogen free railway application EN 45545 9G 0 5 mm 9x splice Item no 16623 5 9970 ENU Change 257119 Approved 2023 02 03 Page 4 11 ebm papst Mulfingen GmbH Co...

Страница 5: ...OP with basic insulation with cable Axial Protection class I with customer connection of protective earth Conformity with standards EN 45545 2 A1 2015 EN 50155 2008 EN 61373 Cat 1B 2010 Approval EAC W...

Страница 6: ...of the cable is connected in a dry environment Only connect the device to circuits that can be switched off with an all pole disconnection switch 4 2 1 Requirements Check whether the information on t...

Страница 7: ...stalled in the winding The motor is provided with a thermal overload protector TOP Always check that the thermal overload protector TOP is properly connected before start up Failure to connect the the...

Страница 8: ...phases Delta connection Y Star connection L1 black L2 blue L3 brown U1 black V1 blue W1 brown U2 green V2 white W2 yellow TOP 2x gray PE green yellow Item no 16623 5 9970 ENU Change 257119 Approved 2...

Страница 9: ...ALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switch...

Страница 10: ...on At least every 6 months Fasten Fastening the protective earth terminal Visual inspection At least every 6 months Fasten Insulation of cables for damage Visual inspection At least every 6 months Rep...