3. TECHNICAL DATA
3.1 Product drawing
All measures have the unit mm.
1
Housing side parts sealed with NBR round cord (pentane-resistant)
2
3-pole strip, mating connector: (not included in standard scope of delivery): tyco No. 350 766-1; female terminal: tyco No. 926 884-1
2.1
L
2.2
N
2.3
PE
3
5-pole strip; mating connector (not included in delivery) Molex No. 39-01-4050, female connector Molex No. 39-00-0059
3.1
(+)
3.2
Speed monitoring
3.3
Not assigned
3.4
PWM input
3.5
(-) GND
4
Bleeder connection for pressure relief possible
Item no. 51283-5-9970 · Revision 79946 · Release 2013-12-02 · Page 5 / 12