FAULTS, POSSIBLE CAUSES AND REMEDIES

 

 
Replace your product by a new one, do not repair it. 
 

 

DANGER 

Electrical voltage at motor 
 

 

Wait five minutes after the voltage 
(all poles) has been switched off 
before opening the product. 

 
 
Fault/  
Error 

Possible cause 

Possible remedial 
action 

Mechanical 
blocking 

Switch off, de-energize 
and eliminate 
mechanical blocking. 

Mains voltage fault  Check mains voltage, 

re-connect voltage 
supply. 

Connection faulty 

Rectify connection, see 
pin connection. 

Motor is too hot 

Allow motor to cool / 
identify cause of fault. 

Motor winding 
interrupted 

Exchange product.  

Motor is not 
rotating 

Ambient 
temperature too 
high 

Reduce ambient 
temperature if possible. 

Impeller out of 
true 

Unbalance of 
rotating parts 

Clean product if still 
unbalanced after 
cleaning, exchange 
product. 

 

 

In case of further faults, contact ebm-
papst. 

 
Technical safety inspection 
 
What requires checking? 

How to 
check? 

Frequency 

Protection against accidental 
contact/ protective clothing 

Visual 
inspection 

min. 1/2 
yearly 

Check product for damage 

Visual 
inspection 

min. 1/2 
yearly 

Fixation of product 

Visual 
inspection 

min. 1/2 
yearly 

Fixation of wires 

Visual 
inspection 

min. 1/2 
yearly 

Insulation of wires 

Visual 
inspection 

min. 1/2 
yearly 

Check impeller for 
wear/sediments/ corrosion 

Visual 
inspection 

min. 1/2 
yearly 

 

COMPLIANCE

 

 
The product bears the CE mark. 
 
The CE mark is affixed to adequately sized nameplates. 
 
Within the meaning of the EMC Guideline 2014/30/EU this document is 
intended as: 
 

Mounting instructions/operating manual as per Art. 18, Paragraph 
(1) 

Installation instructions as per Art. 4 

Operating manual as per Art. 9, Paragraph (3) 

Instructions for use/operating manual as per Art. 18, Paragraph (3) 

Maintenance instructions as per Art.4; Art. 18, Paragraph (1) 

Usage restrictions for residential areas as per Art. 18, Paragraph (2) 
Accompanying documents as per Art. 17, Paragraph (1) 
 
Within the meaning of Directive 2014/35/EU - electrical equipment 
designed  for use within certain voltage limits – this document is 
intended  as: 

Instructions for use/operating manual as per Art. 6, Paragraph (7); 
Art. 8 Paragraph (4) 

 
Within the meaning of the Directive 2006/42/EU Machine Guideline, 
this document is intended as 

Mounting instructions as per Art. 13, Paragraph 1b 

 
The product bears the EAC mark. 
 
The information in this document and in the product data sheet 
applies to mounting, installation, operation, use and maintenance.
 
 

 

Содержание DV5214 N

Страница 1: ...k ratings are used in this operating manual to denote potential risk situations and important safety instructions DANGER This is a potentially dangerous situation and warns of an impending health risk or risk of fatal injury if this warning is not observed Observe this warning WARNING The dangerous situation can occur and can result in major or fatal injuries if the warning is not observed Work wi...

Страница 2: ...loose fitting garments or jewellery when working on moving parts Protect long hair by wearing a hair net WARNING Parts transported by the airflow The product can transport small parts in the airflow and catapult them out Ensure that there are no loose small parts in the intake and exhaust area Do not stand in the danger zone of the product CAUTION High risk of fire spreading Can cause fire to spre...

Страница 3: ...with fully or partially dismantled or manipulated protective equipment Operating the product under conditions other than those mentioned in the technical data Furthermore all fields of application not mentioned under intended use An in situ assessment must be conducted of the heating behavior appropriate and inappropriate operation the protection against contact electrical shocks impact of foreign...

Страница 4: ...hing on again NOTE Electromagnetic compatibility EMC may affect the system integration of the product due to interaction Ensure the electromagnetic compatibility of the entire system Voltage control Speed control via the supply voltage is only permitted within the stipulated supply voltage range Speed control via PWM of the supply voltage is not permitted Requirements Before connecting the product...

Страница 5: ...inspection min 1 2 yearly Fixation of wires Visual inspection min 1 2 yearly Insulation of wires Visual inspection min 1 2 yearly Check impeller for wear sediments corrosion Visual inspection min 1 2 yearly 6 COMPLIANCE The product bears the CE mark The CE mark is affixed to adequately sized nameplates Within the meaning of the EMC Guideline 2014 30 EU this document is intended as Mounting instruc...

Страница 6: ......

Отзывы: