ebm-papst DV4114/2NPU-198 Скачать руководство пользователя страница 4

page 4 of 5 

 

 
Voltage control 
 

 

Speed control via the supply voltage is 
only permitted within the stipulated 
supply voltage range. Speed control via 
PWM of the supply voltage is not 
permitted. 

 
 
 

Requirements: 
 

-  Before connecting the product, ensure that the supply voltage 

corresponds with the product voltage. 

-  Check whether the data on the nameplate corresponds with the 

interface data. 

 

 

Only use cables that are designed for 
the current on the nameplate and the 
corresponding ambient conditions. 
Ensure that the electrical interface data 
is adequately protected (mechanical). 

 
Refer to the nameplate for pin connection. 
 

 

 

 

Colour 

Operation 

Wire 1 

red 

+ UB 

Wire 2 

blue 

- GND 

Wire 3 

violet 

PWM 

Wire 4 

white 

Tacho 

 
The auxilliaries shown on the schematic diagram (which are required 
for the intended use) are not part of our delivery. 
 

Check connections 

 

NOTE

 

 
DC-fans <=60V are products of Protection Class lll and must be 
operated with safety extra-low voltage. 
 

Connect product 

 
Check the product for visible damage and the operability of protective 
equipment before switching on. 
If damage is visible, do not start the product. 
 

FAULTS, POSSIBLE CAUSES AND REMEDIES

 

 
Replace your product by a new one, do not repair it. 
 

 

DANGER 

Electrical voltage at motor 
 

 

Wait five minutes after the voltage 
(all poles) has been switched off 
before opening the product.

 

 

 

Fault/  
Error 

Possible cause 

Possible remedial 
action 

Mechanical 
blocking 

Switch off, de-energize 
and eliminate 
mechanical blocking. 

Mains voltage fault  Check mains voltage, 

re-connect voltage 
supply. 

Connection faulty 

Rectify connection, see 
pin connection. 

Motor is too hot 

Allow motor to cool / 
identify cause of fault. 

Motor winding 
interrupted 

Exchange product.  

Motor is not 
rotating 

Ambient 
temperature too 
high 

Reduce ambient 
temperature if possible. 

Impeller out of 
true 

Unbalance of 
rotating parts 

Clean product if still 
unbalanced after 
cleaning, exchange 
product. 

 

 

In case of further faults, contact ebm-
papst. 

 

Technical safety inspection 
 
What requires checking? 

How to 
check? 

Frequency 

Protection against accidental 
contact/ protective clothing 

Visual 
inspection 

min. 1/2 
yearly 

Check product for damage 

Visual 
inspection 

min. 1/2 
yearly 

Fixation of product 

Visual 
inspection 

min. 1/2 
yearly 

Fixation of wires 

Visual 
inspection 

min. 1/2 
yearly 

Insulation of wires 

Visual 
inspection 

min. 1/2 
yearly 

Check impeller for 
wear/sediments/ corrosion 

Visual 
inspection 

min. 1/2 
yearly 

 

APPROVALS

 

 
The product bears the CE mark. 
 
The CE mark is affixed to adequately sized nameplates. 
 
Within the meaning of the EMC Guideline 2004/108/EU this document 
is intended as: 

 

Mounting instructions as per Art. 9, Paragraph (3) 

Installation instructions as per Art. 3 

Operating manual as per Art. 9, Paragraph (3) 

Instructions for use as per Art. 8, Paragraph (2); Art. 9, Paragraph 
(5) 

Maintenance instructions as per Art.3; Art.9, Paragraph (3) 

Usage restrictions for residential areas as per Art.9, Paragraph (4) 
Accompanying documents as per Annex V, Cl. 3 
 
Within the meaning of Directive 2006/95/EU - use of electrical 
equipment within specific voltage limits - this document is intended 

Instructions for use Art. 10, Paragraph 1 

 
Within the meaning of the Directive 2006/42/EU Machine Guideline, 
this document is intended as 

Mounting instructions as per Art. 13, Paragraph 1b 

 
The information in this document and in the specification applies to 
mounting, installation, operation, use and maintenance. 

Содержание DV4114/2NPU-198

Страница 1: ...risk ratings are used in this operating manual to denote potential risk situations and important safety instructions DANGER This is a potentially dangerous situation and warns of an impending health risk or risk of fatal injury if this warning is not observed Observe this warning WARNING The dangerous situation can occur and can result in major or fatal injuries if the warning is not observed Work...

Страница 2: ...urface CAUTION High temperature at motor housing Risk of burns Provide adequate protection against accidental contact Transport Only transport the product in its original packaging Secure during transport The vibration values temperature and climate ranges should not be exceeded during transport Storage Store the product in a dry and clean environment that is well protected Ensure that the storage...

Страница 3: ...s allowed in so far as this doesn t prevent the normal operation Saline ambient conditions must be avoid Pollution degree 3 according DIN EN 60664 1 It occurs conductive pollution or dry non conductive pollution occurs that becomes conductive due to condensation Ambient conditions Permitted ambient temperature Transport and storage Operation 40 C 80 C 20 C 60 C Vibration and shock load At stationa...

Страница 4: ... too hot Allow motor to cool identify cause of fault Motor winding interrupted Exchange product Motor is not rotating Ambient temperature too high Reduce ambient temperature if possible Impeller out of true Unbalance of rotating parts Clean product if still unbalanced after cleaning exchange product In case of further faults contact ebm papst Technical safety inspection What requires checking How ...

Страница 5: ...page 5 of 5 ...

Отзывы: