3.2 Nominal data

Motor

M4E094-LA

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

ml

ml

Valid for approval /
standard

CE

CE

Speed (rpm) / min

-1

1230

1410

Power input / W

1060

1085

Current draw / A

5.38

5.24

Motor capacitor / µF

10

10

Capacitor voltage / VDB

450

500

Min. back pressure / Pa

0

200

Min. ambient
temperature / °C

-40

-40

Max. ambient
temperature / °C

55

45

Starting current / A

6.0

5.2

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data in accordance with ecodesign regulation EU 327/
2011

Actual

Request 2015

Overall efficiency η

e

/ %

41.1

41

02 Measurement category

B

03 Efficiency category

Total

04 Efficiency grade N

49.1

49

05 Variable speed drive

No

06 Year of manufacture

The year of manufacture is specified on the
rating plate on the product.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
County court Stuttgart · HRA 590344
D-74673 Mulfingen

08 Type

D4E225-EH01-01

09 Power input P

e

/ kW

0.53

09 Air flow q

v

/ m³/h

2115

09 Pressure increase total p

sf

/

Pa

378

10 Speed (rpm) n / min

-1

1415

11 Specific ratio

*

1.00

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

f

/ 100 000 Pa

Data definition with optimum efficiency. The ErP data is determined using a motor-impeller

combination in a standardised measurement configuration.

3.4 Technical features

Mass

15.9 kg

Size

225 mm

Motor size

94

Material of impeller

Sheet steel, galvanised

Housing material

Sheet steel, galvanised

Motor suspension

Motor mounted vibration-free on both sides

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP20

Insulation class

"F"

Humidity (F) /
environmental
protection class (H)

H0 - dry environment

Note ambient
temperature

Occasional start-up between -40 °C and -
25 °C is permissible. For continuous
operation at ambient temperatures below -
25 °C (e.g. refrigeration applications), a
fan version with special low-temperature
bearings must be used.

Mounting position

Any

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Motor protection

Thermal overload protector (TOP)
brought out, basic insulation

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Motor capacitor
according to EN 60252-
1 in safety protection
class

S0

Product conforming
to standard

EN 60034-1 (2010); CE

Approval

EAC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

;

Use the device in accordance with its protection type.

Notes on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may vary during the production period.
Strength, dimensional stability and dimensional accuracy are not affected
by this.
The colour pigments of the paints used react perceptibly to UV light over
the course of time. This does not however have any influence on the
technical properties of the products. To prevent the formation of patches
and fading, the product is to be protected against UV radiation. Changes
in colour are not a reason for complaint and are not covered by the
warranty.

Item no. 12412-5-9970 · ENG · Revision 223007 · Release 2021-02-11 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание D4E225-EH01-01

Страница 1: ...thorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re evaluated once it is installed in the end device The local industrial safety regulations must always be observed when working on the device Keep the workplace clean ...

Страница 2: ...magnetic interferences after integrating the device in installations on the customer s side Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING R...

Страница 3: ...device with an imbalance e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted from the customer system to the fan Operation in medical equipment with a life sustaining or lifesaving function Moving solids content in flow medium Painting the device Connections e g screws coming loose during operation Moving air that c...

Страница 4: ...roduct drawing All measures have the unit mm 1 Connection line ETFE AWG18 6 x brass lead tips crimped Item no 12412 5 9970 ENG Revision 223007 Release 2021 02 11 Page 4 11 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 5: ...of impeller Sheet steel galvanised Housing material Sheet steel galvanised Motor suspension Motor mounted vibration free on both sides Direction of rotation Clockwise seen on rotor Type of protection IP20 Insulation class F Humidity F environmental protection class H H0 dry environment Note ambient temperature Occasional start up between 40 C and 25 C is permissible For continuous operation at amb...

Страница 6: ...tric shock Always install a protective earth first Check the protective earth DANGER Incorrect insulation Risk of fatal injury from electric shock Use only cables that meet the specified installation requirements for voltage current insulation material load etc Route cables such that they cannot be touched by any rotating parts DANGER Electrical load 50 µC between mains wire and protective earth c...

Страница 7: ...t can destroy the winding insulation system and against harmful bearing currents Heating up of the motor when using a frequency converter must be checked by the customer following installation in the end device 4 3 Connection of the cables External leads are brought out of device First connect the PE protective earth connection Connect the lines according to your application When doing so observe ...

Страница 8: ...s 4 4 Connection screen TOP 2 x grey U1 blue Z brown U2 black PE green yellow Item no 12412 5 9970 ENG Revision 223007 Release 2021 02 11 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 9: ...r device Return the device to ebm papst for repair or replacement WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device CAUTION Electrical load on the capacitor after device is switched off Electric shock risk of injury Discharge the capacitors before working on the de...

Страница 10: ...of the ball bearings is designed for a service life of 40 000 hours Please contact ebm papst if bearing replacement is required after this period Adapt the maintenance intervals to the dust pollution occurring 5 2 Safety test What has to be tested How to test Frequency Which measure Check the protective casing against accidental contact for damage and to ensure that it is intact Visual inspection ...

Страница 11: ...inium Non ferrous metal e g motor windings Plastics particularly with brominated flame retardants in accordance with marking Insulating materials Cables and wires Electronic scrap e g circuit boards Only ferrite magnets and not rare earth magnets are used in external rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magnets can be disposed of in the same way as normal iron and steel Electri...

Отзывы: