ebm-papst D4D250-BA02-01 Скачать руководство пользователя страница 8

Operating instructions

D4D250-BA02-01

Translation of the original operating instructions

4.4 Connection diagram

Y

Star connection, three-phase motor

1

Counterclockwise operation

L1

blue

L2

black

L3

brown

PE

green/yellow

TOP

gray

2

Clockwise operation

L1

black

L2

blue

L3

brown

PE

green/yellow

TOP

gray

Item no. 12006-5-9970 · ENU · Change 213948 · Approved 2020-03-25 · Page 8 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание D4D250-BA02-01

Страница 1: ...ably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Bas...

Страница 2: ...Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against...

Страница 3: ...prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration...

Страница 4: ...AL DATA 3 1 Product drawing All dimensions in mm 1 Cable ETFE AWG18 6x crimped splices Item no 12006 5 9970 ENU Change 213948 Approved 2020 03 25 Page 4 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D...

Страница 5: ...mpeller material Sendzimir galvanized sheet steel Housing material Sendzimir galvanized sheet steel Direction of rotation Clockwise viewed toward rotor Degree of protection IP20 Insulation class F Moi...

Страница 6: ...upply and PE connections CAUTION Voltage The device is a built in component and has no disconnecting switch Only connect the device to circuits that can be switched off with an all pole disconnection...

Страница 7: ...pter 4 4 Connection diagram 4 3 1 Motor protection CAUTION Voltage The device is a built in component and has no disconnecting switch Connect the device to a suitable tripping unit Only connect the de...

Страница 8: ...rclockwise operation L1 blue L2 black L3 brown PE green yellow TOP gray 2 Clockwise operation L1 black L2 blue L3 brown PE green yellow TOP gray Item no 12006 5 9970 ENU Change 213948 Approved 2020 03...

Страница 9: ...Live terminals and connections even with device switched off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device CAUTION The motor restarts automat...

Страница 10: ...astening the protective earth terminal Visual inspection At least every 6 months Fasten Insulation of cables for damage Visual inspection At least every 6 months Replace cables Impeller for wear depos...

Страница 11: ...ires are made of similar materials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulators used in the terminal box Power cables Cables for i...

Отзывы: