ebm-papst D3G146-LU03-01 Скачать руководство пользователя страница 5

Operating instructions

D3G146-LU03-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M3G055-CF

Phase

1~

Nominal voltage / VAC

230

Frequency / Hz

50/60

Method of obtaining
data

ml

Speed / min

-1

1330

Power consumption / W

100

Current draw / A

0.8

Min. back pressure / Pa

0

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

50

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

2.4 kg

Fan size

146 mm

Rotor surface

Galvanized

Electronics housing
material

PP plastic, black

Impeller material

PA plastic

Housing material

PP plastic, black

Motor suspension

Motor vibration-damped on both sides

Direction of rotation

Counterclockwise, viewed toward rotor

Degree of protection

Motor IP54, electronics IP20; installation-
and position-dependent

Insulation class

"F"

Installation position

Any

Condensation
drainage holes

None, open rotor

Mode

S1

Motor bearing

Ball bearing

Technical features

- Output 10 VDC, max. 1.1 mA
- Tach output
- Motor current limitation
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from supply
- Thermal overload protection for motor

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

<= 3.5 mA

Electrical hookup

With plug

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Variable

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 60335-1; CE

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Strength class of
screws

8.8

Any further mounting data required can be taken from the product drawing.

3.5 Transport and storage conditions

;

Use the device in accordance with its degree of protection.

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

3.6 Electromagnetic compatibility

EMC immunity to
interference

According to EN 61000-6-2 (industrial
environment)

EMC circuit feedback

According to EN 61000-3-2/3

EMC interference
emission

According to EN 61000-6-3 (household
environment)

Item no. 51143-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание D3G146-LU03-01

Страница 1: ...alled operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to...

Страница 2: ...he user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device R...

Страница 3: ...ve devices Following the operating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e...

Страница 4: ...ch 1 3 0 10V lin PWM 1 4 GND 2 Connector Lumberg 3642 03 K01 pluggable with 3626 03 K01 2 1 PE 2 2 L 2 3 N 3 4x sheet metal nut for thread EN ISO 1478 ST4 8 min screw length 14 5 mm plus material thic...

Страница 5: ...current according to IEC 60990 measuring circuit Fig 4 TN system 3 5 mA Electrical hookup With plug Motor protection Thermal overload protector TOP internally connected with cable Variable Protection...

Страница 6: ...r the data on the nameplate match the connection data Before connecting the device make sure the power supply matches the device voltage Only use cables designed for the current level indicated on the...

Страница 7: ...ector s pin assignment Connect the built in connector with the mating connector Ensure that the connector is properly engaged Item no 51143 5 9970 ENU Change 89188 Approved 2016 04 18 Page 7 11 ebm pa...

Страница 8: ...10 V max 1 1 mA red Voltage output 10 V 1 1 mA electrically isolated not short circuit proof CON11 11 2 Tach white Tach output Open collector 1 pulse per revolution electrically isolated Isink max 10...

Страница 9: ...in the event of the faults described in the table Fault Safety feature description function Rotor position detection error An automatic restart follows Blocked rotor After the blockage is removed the...

Страница 10: ...ge ecological design technical safety and health protection are fixed criteria The following section contains recommendations for ecological disposal of the product and its components 6 2 1 Country sp...

Страница 11: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 51143 5 9970 ENU Change 89188 Approved 2016 04 18 Page 11 11 ebm papst Mulfinge...

Отзывы: