ebm-papst D3G146-AH50-01 Скачать руководство пользователя страница 8

Operating instructions

D3G146-AH50-01

Translation of the original operating instructions

4.4 Connection diagram

Drawing preliminary!

No.

Conn.

Designation

Color

Function/assignment

4

L

black

Power supply 230 VAC, 50-60 Hz, see nameplate for voltage range

3

N

blue

Neutral conductor

1

PE

green/
yellow

Protective earth

8

0-10 V PWM

yellow

Control input 0-10 V or PWM, electrically isolated

9

Tach

white

Tach output: open collector, 1 pulse per revolution, electrically isolated

11

10V / max 1.1
mA

red

Voltage output 10 V/max. 1.1 mA, electrically isolated

12

GND

blue

GND connection for control interface

Item no. 51220-5-9970 · ENU · Change 212353 · Approved 2020-05-07 · Page 8 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание D3G146-AH50-01

Страница 1: ...Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards associated with the device must be assessed again following installation in the final product The locally applicable industrial safety regulations are always to be observed when working on the d...

Страница 2: ...fy that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entan...

Страница 3: ... prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer installation Operation in medical equipment with a life sustaining or life support function Conveying solids in the flow medium Painting the device Connection...

Страница 4: ...t drawing All dimensions in mm 1 Cable PVC AWG22 4x crimped ferrules 2 Cable PVC AWG18 3x crimped ferrules Item no 51220 5 9970 ENU Change 212353 Approved 2020 05 07 Page 4 11 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 5: ...ng material Sheet steel galvanized Motor suspension Motor vibration damped on both sides Direction of rotation Clockwise viewed toward rotor Degree of protection IP44 installation and position dependent Insulation class B Moisture F Environmental H protection class H1 Installation position Shaft horizontal rotor on top or rotor on bottom on request Condensation drainage holes None Mode S1 Motor be...

Страница 6: ...n should be isolated from vibration e g using compensators or similar elements Ensure stress free attachment of the fan to the substructure Check the device for transport damage Damaged devices are not to be installed Install the undamaged device in accordance with your application CAUTION Possible damage to the device If the device slips during installation serious damage can result Ensure that t...

Страница 7: ...ective earth conductor by way of the extra protective earth terminal provided on the device 4 2 2 Reactive currents Because of the EMC filter integrated for compliance with EMC limits interference emission and immunity to interference reactive currents can be measured in the supply line even when the motor is at a standstill and the line voltage is switched on The values are typically in the range...

Страница 8: ...ctive earth 8 0 10 V PWM yellow Control input 0 10 V or PWM electrically isolated 9 Tach white Tach output open collector 1 pulse per revolution electrically isolated 11 10V max 1 1 mA red Voltage output 10 V max 1 1 mA electrically isolated 12 GND blue GND connection for control interface Item no 51220 5 9970 ENU Change 212353 Approved 2020 05 07 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachmühle...

Страница 9: ...r e g in cyclic operation on and off via power supply Disconnect the device from the power supply When disconnecting be sure to disconnect the ground connection last 5 INTEGRATED PROTECTIVE FEATURES The integrated protective functions cause the motor to switch off automatically in the event of the faults described in the table Fault Safety feature description function Rotor position detection erro...

Страница 10: ...aning does not eliminate vibrations the fan may need to be rebalanced To have it rebalanced contact ebm papst The fan is equipped with maintenance free ball bearings The lifetime lubrication of the ball bearings is designed for a service life of 40 000 hours If bearing replacement is necessary after that period contact ebm papst Adapt the maintenance intervals to the actual level of dust exposure ...

Страница 11: ...etallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plastics particularly with brominated flame retardants in accordance with marking Insulating materials Cables and wires Electronic scrap e g circuit boards Only ferrite magnets and not rare earth magnets a...

Отзывы: