2. Specification 

 

This is a stationary Class I motor -appliance with a fixed supply lead 
Manufacturer: ebm-papst UK ltd 
Part number: COOL500EC-230 
Voltage: 230 V 50/60 Hz 
Current: rated for maximum 2.2 Amp 
Ambient temperature: Maximum 55

o

Protection: IP54 
Commission regulation (EU) 327|2011: the fan integrated within the appliance is part 
number A3G500-AD01-51 and conforms to the requirement of the regulation.   

 

Figure 1 - EC Aura 

 

3   Use of connection converter plug 

3.1 General 

The appliance is supplied fitted with a supply cord and plug. The plug is a ‘schuko’ 
type  plug  to  DIN  VDE  0620  with  a  converter  plug  fitted  over  the  ‘schuko’  plug  for 
connection to a standard UK socket to BS 1363. 
If the appliance is to be used in a country that has mains socket suitable for use with 
a ‘schuko’ plug then the converter plug can be removed with simple tools. 

 

3.2 Warning 

The  converter  plug  should  not  be  removed  whilst  connected  to  a  mains  socket. 
Disconnect from the mains before proceeding to 3.3 

 
 

Содержание COOL500EC-115

Страница 1: ...e Instructions Operation and Maintenance Instructions for EC Aura 230V Document no 210 OMI10013 40 Issue 5 Part No COOL500EC 230 Manufacturer ebm papst UK Ltd Stationary class 1 motor operated appliance with a fixed supply cord ...

Страница 2: ...uipment 7 7 End of life 7 8 Take back policy 7 9 Data sheet 9 10 Certificate of Conformity 10 Figure 1 EC Aura 4 Figure 2 As supplied converter plug fitted 5 Figure 3 loosening of screws of converter plug 5 Figure 4 releasing of the barbed clips or the top housing 6 Figure 5 picture showing schuko plug inside converter plug 6 Figure 6 control panel sub assembly 8 Figure 7 housing sub assembly 8 Fi...

Страница 3: ...uards Keep guards clear from obstructions Do not operate appliance in an explosive atmosphere If the supply cord is damaged it must be replaced by the manufacturer or its service agent or similarly qualified person Isolate the appliance by disconnecting the plug and supply cord from the mains socket The switch on the appliance does not isolate the appliance Do not move the appliance during operati...

Страница 4: ...of the regulation Figure 1 EC Aura 3 Use of connection converter plug 3 1 General The appliance is supplied fitted with a supply cord and plug The plug is a schuko type plug to DIN VDE 0620 with a converter plug fitted over the schuko plug for connection to a standard UK socket to BS 1363 If the appliance is to be used in a country that has mains socket suitable for use with a schuko plug then the...

Страница 5: ...ce is supplied with the converter plug fitted over the schuko plug as shown in figure 1 Figure 2 As supplied converter plug fitted The screws of the converter plug are loosened as shown in figure 2 Figure 3 loosening of screws of converter plug ...

Страница 6: ... small screw driver as shown in figure 3 to release the barbed clips Figure 4 releasing of the barbed clips or the top housing The top housing is then lifted allowing removal of the schuko plug see figure 5 Figure 5 picture showing schuko plug inside converter plug ...

Страница 7: ...ing a suitably qualified person in order to avoid a hazard 6 WEEE waste electrical and electronic equipment ebm papst UK Ltd complies with the Waste Electrical and Electronic Equipment WEEE Regulations through membership of a producer compliance scheme PCS as a B2B producer EEE Producer registration number WEE CA0209WR 7 End of life This product has been designed to consider re use and end of life...

Страница 8: ...8 Figure 6 control panel sub assembly Figure 7 housing sub assembly Figure 8 trolley sub assembly ...

Страница 9: ...9 9 Data sheet ...

Страница 10: ...10 10 Certificate of Conformity ...

Отзывы: