EBM ALPHA 

WARNING 

Terminals and connections have voltage  even 

with a unit that is shut off 

Electric shock 

 

Wait five minutes after disconnecting the voltage 

at all poles before opening the device. 

CAUTION 

In the event of failure, there is electric voltage at 

the rotor 

The rotor is base insulated. 

 

Do not touch the rotor once it is installed. 

CAUTION 

The motor restarts automatically when operating 

voltage is applied, e.g. after a power failure. 

Danger of injury 

 

Keep out of the danger zone of the device. 

 

When working on the device, switch off the mains 

supply voltage and secure the latter from being 

switched on again. 

 

Wait until the device stops. 

 

After working on the device, remove any used 

tool or other objects from the device. 

1.5

 

Mechanical movement 

DANGER 

Flying parts 

If the motor is operated, particles could be ejected 

from the surface and cause bodily injuries. 

→ Keep out of operating area when the device is 

switched on. 

DANGER  

Rotating device 

Body parts that come into contact with the rotor can 

be injured. 

 

Secure the device against accidental contact. 

 

Before working on the system/machine, wait until 

all parts have come to a standstill. 

Long hair, loose items of clothing and jewellery could 

become entangled and pulled into the device. You 

could be injured. 

 

Do not wear any loose clothing or jewellery while 

working on rotating parts. 

 

Protect long hair by wearing a cap. 

1.6

 

Hot surface

 

CAUTION

 

 

High temperature at the motor housing 

Danger of burn injuries 

 

Ensure that sufficient protection against 

accidental contact is provided. 

1.7

 

Transport

 

CAUTION 

Transport of device 

 

Wear safety shoes and cut-resistant safety 

gloves. 

 

Transport the device in its original packaging 

only. 

 

Secure the device so that it does not slip, e.g. by 

using a clamping strap. 

1.8

 

Storage

 

 

Store the device, partially or fully assembled, in a dry and 

weatherproof manner in the original packing in a clean 

environment. 

 

Protect the device from environmental impacts and dirt 

until the final installation. 

 

We recommend storing the device for a maximum up to 

one year to guarantee proper operation and longest 

possible service life. 

 

Even devices explicitly suited for outdoor use are to be 

stored as described prior to being commissioned. 

 

Maintain the storage temperature, see chapter 3.5 

Transport and storage conditions. 

1.9

 

Disposal

 

When disposing of the device, please comply with all relevant 

requirements and regulations applicable in your country. 

Содержание ALPHA

Страница 1: ...device If the device is sold or transferred the operating instructions must accompany it These operating instructions may be duplicated and forwarded for information about potential dangers and their...

Страница 2: ...Rotating device Body parts that come into contact with the rotor can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a s...

Страница 3: ...this product is installed Proper use also includes Using the device in accordance with the permitted ambient temperature see chapter 3 5 Transport and storage conditions and chapter 3 2 Nominal data...

Страница 4: ...3 9360 6464 ABN 33 115 927 556 NSW Phone 61 02 9827 6400 NSW Fax 61 02 9827 6464 NZ Phone 64 09 525 0245 NZ Fax 64 09 525 0246 sales ebmpapst com au www ebmpapst com au EBM ALPHA 3 TECHNICAL DATA 3 1...

Страница 5: ...type of protection IP 44 depending on installation and position Junction box type of protection Must be stored in a dry environment Insulation class B Humidity class F1 2 Mounting position Any Conden...

Страница 6: ...agree with the connection data and the data of the operating capacitor Before connecting the device ensure that the supply voltage matches the operating voltage of the device Only use cables designed...

Страница 7: ...h for the supply line When disconnecting be sure to disconnect the earth wire connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Return t...

Страница 8: ...r high pressure washer Do not use any cleaners containing acids bases or solvents Do not use any pointed or sharp edged objects to clean 5 2 Safety test What has to be tested How to test Frequency Whi...