background image

Operating instructions

A6E500-AJ03-01

Tr

anslation of the or

iginal oper

ating instr

uctions

Impeller running

roughly

Imbalance in rotating

parts

Clean the device; if

imbalance is still

evident after cleaning,

replace the device.

If you have

attached any weight

clips during cleaning,

make sure to remove

them afterwards.

Motor does not turn

Mechanical blockage Switch off, de-

energise, and

remove mechanical

blockage.

Mains supply voltage

faulty

Check mains supply

voltage,

restore power

supply.

Faulty connection

De-energise, correct

connection, see

connection diagram.

Thermal overload

protector responded

Allow motor to cool

off, locate and rectify

cause of error, if

necessary cancel

restart lock-out

Unacceptable

operating point

Check operating point

Overtemperature of

motor

Ambient temperature

too high

Lower ambient

temperature if possible

Insufficient cooling

Improve cooling

If you have any other problems, contact ebm-papst.

5.1 Cleaning

NOTE

Damage to the device during cleaning

Malfunction possible
→ Do not clean the device using a water jet or high-pressure

cleaner.

→ Do not use any acid, alkali or solvent-basedcleaning

agents.

→ Do not use any pointed or sharp-edged objects for cleaning

5.2 Safety test

What has to

be tested?

How to test?

Frequency

Which

measure?

Check the

protective

casing against

accidental

contact for

damage and to

ensure that it is

intact

Visual inspection At least every

6 months

Repair or

replacement of

the device

Check the

device for

damage to

blades and

housing

Visual inspection At least every

6 months

Replacement of

the device

Mounting the

connection lines

Visual inspection At least every

6 months

Fasten

Mounting of

protective earth

connection

Visual inspection At least every

6 months

Fasten

Check the

insulation of the

wires for damage

Visual inspection At least every

6 months

Replace wires

Tightness of

screwed cable

gland

Visual inspection At least every

6 months

Retighten,

replace if

damaged

Condensate

discharge holes

for clogging, as

necessary

Visual inspection At least every

6 months

Open bore holes

Weld seams for

crack formation

Visual inspection At least every

6 months

Replace device

Abnormal

bearing noise

acoustic

At least every

6 months

Replace device

5.3 Disposal

For ebm-papst, environmental protection and resource preservation are

top priority corporate goals.

ebm-papst operates an environmental management system which is

certified in accordance with ISO 14001 and rigorously implemented

around the world on the basis of German standards.

Right from the development stage, ecological design, technical safety

and health protection are fixed criteria.

The following section contains recommendations for ecological disposal

of the product and its components.

5.3.1 Country-specific legal requirements

NOTE

Country-specific legal requirements

Always observe the applicable country-specific legal

regulations with regard to the disposal of products or waste

occurring in the various phases of the life cycle. The

corresponding disposal standards are also to be heeded.

5.3.2 Disassembly

Disassembly of the product must be performed or supervised by

qualified personnel with the appropriate technical knowledge.

The product is to be disassembled into suitable components for disposal

employing standard procedures for motors.

WARNING

Heavy parts of the product may drop off. Some of the

product components are heavy. These components

could drop off during disassembly.

This can result in fatal or serious injury and material damage.
→ Secure components before unfastening to stop them falling.

5.3.3 Component disposal

The products are mostly made of steel, copper, aluminium and plastic.

Metallic materials are generally considered to be fully recyclable.

Separate the components for recycling into the following categories:

Steel and iron

Aluminium

Non-ferrous metal, e.g. motor windings

Item no. 10089-5-9970 · ENG · Revision 98149 · Release 2018-07-24 · Page 11 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание A6E500-AJ03-01

Страница 1: ......

Страница 2: ... technical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re evaluated once it is installed in the end device The local industrial safety regulations must always be observed when working on the device K...

Страница 3: ...vement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair dangling items of clothing jewellery and similar items can become entangled and be pulled into the device Risk of injury Do not we...

Страница 4: ...ited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted from the customer system to the fan Operation in medical equipment with a life sustaining or lifesaving function Moving solids content in flow medium Painting the device Connections e g screws coming...

Страница 5: ...m 1 Direction of air flow V 2 Screw depth max 12 mm 3 Tightening torque 1 5 0 2 Nm 4 Cable diameter min 6 mm max 12 mm tightening torque 2 0 3 Nm Item no 10089 5 9970 ENG Revision 98149 Release 2018 07 24 Page 4 12 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 6: ...nected by customer Motor capacitor according to EN 60252 1 in safety protection class S0 Product conforming to standard EN 61800 5 1 Approval CSA C22 2 no 100 CCC VDE UL 1004 1 EAC For cyclic speed loads note that the rotating parts of the device are designed for maximum one million load cycles If you have specific questions contact ebm papst for support Use the device in accordance with its prote...

Страница 7: ...GER Incorrect insulation Risk of fatal injury from electric shock Use only cables that meet the specified installation requirements for voltage current insulation material load etc Route cables such that they cannot be touched by any rotating parts DANGER Electrical load 50 µC between mains wire and protective earth connection after switching of the supply when switching multiple devices in parall...

Страница 8: ...he customer following installation in the end device 4 3 Connection in terminal box 4 3 1 Preparing connection lines for the connection Strip the cable just enough so that the screwed cable gland is tight and the terminals are relieved of strain Tightening torque see chapter 3 1 Product drawing NOTE Tightness and strain relief depend on the cable used The user must check this 4 3 2 Connecting cabl...

Страница 9: ... prevent it from being switched back on NOTE Lack of motor protection Without motor protection the motor can overheat and suffer damage Connect up the thermal overload protector installed in the coil The motors are equipped with thermal overload protectors to protect the devices Check to make sure that the thermal overload protector is correctly connected before each operation Failure to connect u...

Страница 10: ...s 4 4 Connection screen L U1 blue Z brown N U2 black PE green yellow TOP grey Item no 10089 5 9970 ENG Revision 98149 Release 2018 07 24 Page 9 12 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 11: ...operate free of vibrations throughout its speed control range Strong vibrations can result from improper handling imbalance resulting from damage during transport or component induced or structural resonances When putting the fan into service determine the speed ranges with excessive vibration levels and also any resonance frequencies that may be present When regulating the speed pass through reso...

Страница 12: ... if damaged Condensate discharge holes for clogging as necessary Visual inspection At least every 6 months Open bore holes Weld seams for crack formation Visual inspection At least every 6 months Replace device Abnormal bearing noise acoustic At least every 6 months Replace device 5 3 Disposal For ebm papst environmental protection and resource preservation are top priority corporate goals ebm pap...

Страница 13: ...l insulating materials on the product in cables and wires are made of similar materials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulators used in the terminal box Power lines Cables for internal wiring Electrolytic capacitors Dispose of electronic components employing the proper procedures for electronic scrap Please contact ebm paps...

Отзывы: