ebm-papst A3G910-AO84-35 Скачать руководство пользователя страница 4

Operating instructions

A3G910-AO84-35

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Direction of air flow "A"

2

Max. clearance for screw 16 mm

3

Cable diameter min. 4 mm, max. 10 mm, tightening torque 2.5 ± 0.4 Nm

4

Tightening torque 3.5 ± 0.5 Nm

Item no. 55758-5-9970 · ENU · Change 200267 · Approved 2018-07-27 · Page 4 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

E-mail: [email protected]  

Содержание A3G910-AO84-35

Страница 1: ...permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards associated with the device...

Страница 2: ...wing installation appropriate shielding measures have to be taken by the user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire s...

Страница 3: ...e within the permitted ambient temperature range see Chapter 3 6 Transport and storage conditions and Chapter 3 2 Nominal data Operating the device with all protective devices Following the operating...

Страница 4: ...A 2 Max clearance for screw 16 mm 3 Cable diameter min 4 mm max 10 mm tightening torque 2 5 0 4 Nm 4 Tightening torque 3 5 0 5 Nm Item no 55758 5 9970 ENU Change 200267 Approved 2018 07 27 Page 4 12...

Страница 5: ...ncy level The ErP data is determined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Weight 13 5 kg Size 910 mm Motor size 112 Rotor surface Painted bl...

Страница 6: ...it by only the blades near the hub Strictly avoid shocks Wear safety shoes and cut resistant safety gloves CAUTION Heavy load when unpacking device Risk of physical injury such as back injuries Two pe...

Страница 7: ...liance with EMC limits interference emission and immunity to interference reactive currents can be measured in the supply line even when the motor is at a standstill and the line voltage is switched o...

Страница 8: ...alled lying flat Make sure the cable is routed in a U shaped loop Fig 3 Fan installed lying flat cable routed in a U shaped loop Fans installed upright When routing the cable make sure that the cable...

Страница 9: ...2 8 GND Reference ground for control interface SELV KL3 3 7 0 10 V Control current sensor value input 0 10 VDC impedance 100 k use only as alternative to 4 20 mA input SELV KL3 4 10 V Voltage output...

Страница 10: ...operation on and off via power supply Switching off the device for maintenance Switch off the device via the control input Do not switch the motor e g in cyclic operation on and off via power supply...

Страница 11: ...ebalanced To have it rebalanced contact ebm papst The fan is equipped with maintenance free ball bearings The lifetime lubrication of the ball bearings is designed for a service life of 40 000 hours I...

Страница 12: ...s are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plastics particularly...