ebm-papst A3G400-AC22-51 Скачать руководство пользователя страница 9

Operating instructions

A3G400-AC22-51

Translation of the original operating instructions

4.4 Connection screen

Item no. 50736-5-9970 · ENG · Revision 211129 · Release 2020-07-14 · Page 9 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание A3G400-AC22-51

Страница 1: ...nstall the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re eval...

Страница 2: ...installations on the customer s side Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be...

Страница 3: ...and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted from...

Страница 4: ...of air flow V 2 Depth of screw 8 10 mm 3 Connection line PVC AWG 18 5 x crimped core end sleeves 4 Connection line PVC AWG 22 3x crimped core end sleeves Item no 50736 5 9970 ENG Revision 211129 Rele...

Страница 5: ...ErP data is determined using a motor impeller combination in a standardised measurement configuration 3 4 Technical features Mass 4 2 kg Size 400 mm Motor size 84 Surface of rotor Coated in black Mat...

Страница 6: ...it by the centre of the blades only Make sure to avoid any shock Wear safety shoes and cut resistant safety gloves CAUTION The blades of the impeller could be damaged Set down the fan carefully on a...

Страница 7: ...sured even when the motor is at a standstill and the mains voltage is switched on The values are typically in the range 250 mA At the same time the effective power in this operating state operational...

Страница 8: ...Fans installed in upright position Fig 2 Cable routing for fans installed in upright position The cables must always be routed downwards Item no 50736 5 9970 ENG Revision 211129 Release 2020 07 14 Pag...

Страница 9: ...inal operating instructions 4 4 Connection screen Item no 50736 5 9970 ENG Revision 211129 Release 2020 07 14 Page 9 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 7938 81...

Страница 10: ...sure to disconnect the earth wire connection last 5 INTEGRATED PROTECTIVE FUNCTIONS The integrated protective functions cause the motor to switch off automatically in case of faults described in the t...

Страница 11: ...for cleaning Completely remove any cleaning agents used Immediately switch off and replace the device if severe corrosion is apparent at load bearing or rotating parts Repairs to load bearing or rota...

Страница 12: ...components are heavy These components could drop off during disassembly This can result in fatal or serious injury and material damage Secure components before unfastening to stop them falling 6 3 3 C...

Отзывы: