3.2 Nominal data

Motor

M2S052-CA

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Method of obtaining
data

fa

fa

Valid for approval/
standard

CE

CE

Speed (rpm) / min

-1

2800

3250

Power consumption / W

45

39

Current draw / A

0.31

0.25

Max. back pressure / Pa

80

120

Min. ambient
temperature / °C

-25

-25

Max. ambient
temperature / °C

50

70

Starting current / A

0.45

0.40

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

0.86 kg

Size

130 mm

Motor size

52

Rotor surface

Rotor open, painted black

Blade material

Sheet steel, painted black

Number of blades

7

Airflow direction

V

Direction of rotation

Counterclockwise, viewed toward rotor

Degree of protection

IP20

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H0+

Installation position

Any

Condensation
drainage holes

None, open rotor

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Variable

Protection class
assignment

I; If a protective earth is connected by
the customer to the marked PE
connection point.
This component for installation may
have several local protection classes.
This information relates to this
component’s basic design.
The final protection class is based on
the component’s intended installation and
connection.

Conformity with
standards

EN 60034-1; EN 60204-1; EN 60335-1;
CE

Approval

CCC; EAC; UL 507; VDE; CSA
C22.2 No. 113

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. The product is to be protected against UV radiation to
prevent the formation of patches and fading. Changes in color are not a
reason for complaint and are not covered by the warranty. UV radiation
in the frequency range and the intensity of natural solar radiation has no
effect on the technical properties of the products.

3.4 Mounting data

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

Strength class of
screws

8.8

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 11008-5-9970 · ENU · Change 220349 · Approved 2021-10-25 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание A2S130-AA03-01

Страница 1: ...and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the elect...

Страница 2: ...ndstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the device Injuries can result Do not wear any loose fitting or da...

Страница 3: ...ing the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer...

Страница 4: ...drawing All dimensions in mm 1 Cable AWG20 2x splice 2 Airflow direction V 3 Max clearance for screw 5 mm Item no 11008 5 9970 ENU Change 220349 Approved 2021 10 25 Page 4 11 ebm papst Mulfingen GmbH...

Страница 5: ...ction Conformity with standards EN 60034 1 EN 60204 1 EN 60335 1 CE Approval CCC EAC UL 507 VDE CSA C22 2 No 113 With regard to cyclic speed loads note that the rotating parts of the device are design...

Страница 6: ...switched off with an all pole disconnection switch 4 2 1 Requirements Check whether the information on the nameplate matches the connection data Before connecting the device make sure the power supply...

Страница 7: ...st connect the PE protective earth Connect the cables according to your application When doing so observe Chapter 4 4 Connection diagram Item no 11008 5 9970 ENU Change 220349 Approved 2021 10 25 Page...

Страница 8: ...ons 4 4 Connection diagram L black N black TOP thermal overload protector Item no 11008 5 9970 ENU Change 220349 Approved 2021 10 25 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfin...

Страница 9: ...ure to disconnect the ground connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WA...

Страница 10: ...Abnormal bearing noise acoustic At least every 6 months Replace device 5 3 Disposal For ebm papst environmental protection and resource preservation are top priority corporate goals ebm papst operate...

Страница 11: ...omponents employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 11008 5 9970 ENU Change 220349 Approved 2021 10 25 Page 11 11 ebm pa...

Отзывы: