ebm-papst A2D300-AP02-01 Скачать руководство пользователя страница 5

Operating instructions

A2D300-AP02-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M2D074-DF

Phase

3~

3~

3~

3~

Nominal voltage / VAC

230

230

400

400

Connection

Δ

Δ

Y

Y

Frequency / Hz

50

60

50

60

Type of data definition

fa

fa

fa

fa

Valid for approval /
standard

CE

CE

CE

CE

Speed / min

-1

2580

2750

2580

2750

Power input / W

210

300

210

300

Current draw / A

0.62

0.84

0.36

0.48

Max. back pressure / Pa

200

125

200

125

Min. ambient temperature
/ °C

-25

-25

-25

-25

Max. ambient
temperature
/ °C

75

40

75

40

Starting current / A

2.0

1.9

1.16

1.1

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

29.9

25.9

29.9

Efficiency grade N

40

36

40

Power input P

e

/ kW

0.25

Air flow q

v

/ m³/h

2210

Pressure increase total p

sf

/ Pa

125

Speed n / min

-1

2455

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

3.2 kg

Size

300 mm

Surface of rotor

Coated in black

Material of blades

Sheet steel, coated in black

Number of blades

5

Direction of air flow

"V"

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position as per EN 60034-5

Insulation class

"F"

Humidity class

F1-2

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1, motor does not have
factory-installed overheating protection

Approval

CCC; EAC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 10364-5-9970 · Revision 82795 · Release 2014-05-08 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание A2D300-AP02-01

Страница 1: ...al staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any...

Страница 2: ...nd impeller can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair loose item...

Страница 3: ...tions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that c...

Страница 4: ...ve the unit mm 1 Direction of air flow V 2 Depth of screw max 10 mm 3 Connection line PFA AWG20 green yellow AWG18 7x lead tips crimped Item no 10364 5 9970 Revision 82795 Release 2014 05 08 Page 4 9...

Страница 5: ...Direction of air flow V Direction of rotation Counter clockwise seen on rotor Type of protection IP 44 Depending on installation and position as per EN 60034 5 Insulation class F Humidity class F1 2 M...

Страница 6: ...fore connecting the device ensure that the supply voltage matches the operating voltage of the device Only use cables designed for current according to the type plate For determining the cross section...