ebm-papst A2D250-AI14-10 Скачать руководство пользователя страница 5

Operating instructions

A2D250-AI14-10

Translation of the original operating instructions

3.2 Nominal data

Motor

M2D068-CC

Phase

3~

3~

3~

3~

Nominal voltage / VAC

208

220

220

230

Connection

Δ

Δ

Δ

Δ

Frequency / Hz

60

50

60

50

Type of data definition

fa

fa

fa

fa

Valid for approval /
standard

CE

CE

CE

CE

Speed / min

-1

2350

2370

2440

2460

Power input / W

128

102

135

110

Current draw / A

0.40

0.33

0.40

0.33

Max. back pressure / Pa

84

93

93

100

Min. ambient temperature
/ °C

-25

-25

-25

-25

Max. ambient
temperature
/ °C

60

80

60

80

Phase

3~

3~

3~

3~

Nominal voltage / VAC

230

265

360

380

Connection

Δ

Δ

Y

Y

Frequency / Hz

60

60

60

50

Type of data definition

fa

fa

fa

fa

Valid for approval /
standard

CE

CE

CE

CE

Speed / min

-1

2580

2750

2350

2370

Power input / W

140

160

128

102

Current draw / A

0.38

0.40

0.23

0.19

Max. back pressure / Pa

100

120

84

93

Min. ambient temperature
/ °C

-25

-25

-25

-25

Max. ambient
temperature
/ °C

60

60

60

80

Phase

3~

3~

3~

3~

Nominal voltage / VAC

380

400

400

460

Connection

Y

Y

Y

Y

Frequency / Hz

60

50

60

60

Type of data definition

fa

fa

fa

fa

Valid for approval /
standard

CE

CE

CE

CE

Speed / min

-1

2440

2460

2580

2750

Power input / W

135

110

140

160

Current draw / A

0.23

0.19

0.22

0.23

Max. back pressure / Pa

93

100

100

120

Min. ambient temperature
/ °C

-25

-25

-25

-25

Max. ambient
temperature
/ °C

60

80

60

60

Phase

3~

Nominal voltage / VAC

480

Connection

Y

Frequency / Hz

60

Type of data definition

fa

Valid for approval /
standard

CE

Speed / min

-1

2680

Power input / W

170

Current draw / A

0.23

Max. back pressure / Pa

110

Min. ambient temperature
/ °C

-25

Max. ambient
temperature
/ °C

65

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Technical features

Mass

1.9 kg

Size

250 mm

Surface of rotor

Coated in black

Material of blades

Sheet steel, coated in black

Number of blades

9

Direction of air flow

"A"

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position as per EN 60034-5

Insulation class

"F"

Humidity class

F2-2

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1

Approval

CSA C22.2 Nr.100; UL 1004-1

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

Item no. 12218-5-9970 · Revision 76115 · Release 2012-03-06 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание A2D250-AI14-10

Страница 1: ...ied trained and authorised technical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety r...

Страница 2: ...wellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emissi...

Страница 3: ...tions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that c...

Страница 4: ...sures have the unit mm 1 Direction of air flow A 2 Depth of screw max 5 mm 3 Connection line PFA 4G 4x brass lead tips crimped Item no 12218 5 9970 Revision 76115 Release 2012 03 06 Page 4 10 ebm paps...

Страница 5: ...ge VAC 480 Connection Y Frequency Hz 60 Type of data definition fa Valid for approval standard CE Speed min 1 2680 Power input W 170 Current draw A 0 23 Max back pressure Pa 110 Min ambient temperatur...

Страница 6: ...s that meet the specified installation requirements for voltage current insulation material load etc Route cables such that they cannot be touched by any rotating parts CAUTION Electrical voltage The...

Страница 7: ...requency converter only after consultation with ebm papst Fit sinusoidal filters that work on all poles live live and live earth between the frequency inverter and the motor for operation with frequen...

Страница 8: ...ion of rotation by reversing two phases Three phase motor Y Star connection L1 black L2 blue L3 brown PE green yellow Item no 12218 5 9970 Revision 76115 Release 2012 03 06 Page 8 10 ebm papst Mulfing...

Страница 9: ...ltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device CAUTION The motor restarts automatically when operating...

Страница 10: ...eplacement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least...