INTENDED USE

 

 
The product is designed exclusively as a built-in device for conveying 
air according to the technical data. 
Every use that is not in accordance with the intended purpose, is 
regarded as misuse of the product. 
On-site installations must comply with the mechanical, thermal and 
service life requirements, see Chapter 3, Technical Data. 
 
Intended use includes: 
 
-  Operating the product with all protective equipment 
-  Do not put the product into operation before it has been installed in 

the customer's application 

-  Observation of the operating manual 
 
Use for other than the intended purpose 
 
Using the product for the purposes mentioned below is prohibited and 
can be dangerous: 
 
-  Conveyance of air that contains abrasive particles. 
-  Conveyance of air that has a highly corrosive effect. 
-  Conveyance of air that has a high dust load, e.g. vacuuming 

sawdust. 

-  Conveyance of inflammable gases/particles. 
-  Contact with materials that can damage the product, e.g. acids, 

caustic solutions, solvents. 

-  Exposure to radiation that can damage product components, e.g. 

strong UV rays or thermal radiation. 

-  Operating during external vibration. 
-  Operating the product close to inflammable materials or 

components. 

-  Operating the product in an explosive atmosphere 
-  Use of the prouct as a safety component or for performing safety-

relevant functions. 

-  Operating in medical devices with life-sustaining or life-saving 

function if not validated together with ebm-papst. 

-  Operating in non-stationary systems, e.g. railway vehicles, aircraft 

and spacecraft if not validated together with ebm-papst. 

-  Operating with fully or partially dismantled or manipulated protective 

equipment. 

-  Operating the product under conditions other than those mentioned 

in the technical data. 

-  Furthermore, all fields of application not mentioned under intended 

use. 

 
An in situ assessment must be conducted of the heating behavior 
(appropriate and inappropriate operation), the protection against 
contact, electrical shocks, impact of foreign objects or water and the 
usage at altitudes higher than 2000 meters. 
 
Contact ebm-papst if you have specific queries regarding the product.

TECHNICAL DATA

 

 
Drawing, see annex 
 
Technical description 
 
Airflow direction 

Air outlet over struts 

Rotating direction looking 
at rotor 

Counterclockwise 

Nominal voltage 

12,0 V 

Current consumption 

300 mA 

Power consumption 

3,6 W 

Speed 

4.400 1/min 

Max. free-air flow 

82,0 m3/h 

Mass 

0,110 kg 

Protection class 

III 

Max. torque when 
mounted across both 
mounting flanges 

Wire outlet corner: 30 Ncm 
Remaining corners: 50 Ncm 

Screw size 

ISO 4762 - M4 degreased, 
without an additional brace and 
without washer 

 
The product is intended for use in sheltered rooms with controlled 
temperature and controlled humidity. Directly exposure to water must 
be avoided. 
 
Pollution degree 1 (according DIN EN 60664-1) 
There is either no pollution or it occurs only dry, non-conductive 
pollution. The pollution has no negative impact. 
 
 
 
Ambient conditions 
 
Permitted ambient temperature 
Transport and storage 

Operation 

-40 °C ... 80 °C 

-20 °C ... 60 °C 

 
Vibration and shock load 
 
The mechanical Vibration and Shock data for the product is available. 
If the operation of the product should take place in a sinusoidal 
vibration containing environment or fixing the product on sinusoidal 
vibrating surface, please contact our technical support. 
 
Do not operate your product in the resonance range. 