CONNECTION AND COMMISSIONING

 

 
Connect mechanical parts 
 

 

CAUTION 
Risk of cutting/squashing when 
removing the product from the 
packaging and during mounting. 
 
Grasp the housing and lift the product 
carefully out of the packaging. Avoid 
impact. 

 

Wear safety boots and cut-resistant 
gloves. 

 

 

NOTE 
Risk of damage to electronic 
components. 
 

 

Use ESD protective equipment when 
mounting. 

 
 
 
 

Connect electrical parts 
 
Connect to the mains after installation. 
 

 

DANGER 
Compliance with the electrical 
installation regulations 
 

 

Observe the connection regulations 
that are valid in your country. (e.g. 
fusing, GFCI) 

 

 

CAUTION 
Electrical voltage 
The product is a built-in 
component and has no switch for 
disconnecting power.
 
 

 

Only connect the product to 
current circuits that can be 
switched off by a switch (all poles 
disconnected). When working on 
the product, secure the 
system/machine in which the 
product is installed against 
switching on again. 

 
 
NOTE 
Electromagnetic compatibility (EMC) may affect the system integration 
of the product due to interaction. 
 

 

Ensure the electromagnetic compatibility of the entire system. 

 

 
Voltage control 
 

 

Speed control via the supply voltage is 
only permitted within the stipulated 
supply voltage range. Speed control via 
PWM of the supply voltage is not 
permitted. 

 
 
 
Requirements: 
 
-  Before connecting the product, ensure that the supply voltage 

corresponds with the product voltage. 

-  Check whether the data on the nameplate corresponds with the 

interface data. 

 

 

Only use cables that are designed for 
the current on the nameplate and the 
corresponding ambient conditions. 
Ensure that the electrical interface data 
is adequately protected (mechanical). 

 
Find additional information in drawing or label. 
 

 

 

Wire 

Color 

Operation 

red 

+ UB 

blue 

- GND 

violet 

PWM 

white 

Tacho 

 
The auxilliaries shown on the schematic diagram (which are required 
for the intended use) are not part of our delivery. 
 
Check connections 
 
NOTE 
DC-fans >60V are products of Protection Class l and must be earthed. 
Connect product 
 
Check the product for visible damage and the operability of protective 
equipment before switching on. 
If damage is visible, do not start the product.

Содержание 6318 N/2H3PU

Страница 1: ...n making enquiries about the product ebm papst St Georgen GmbH Co KG Hermann Papst Straße 1 D 78112 St Georgen Phone 49 0 7724 81 0 Fax 49 0 7724 81 1309 info2 de ebmpapst com www ebmpapst com As per 20 03 2018 Version 1 2 Article number 9695480302 Original operating manual INDEX 1 SAFETY REGULATIONS AND INFORMATION 2 2 INTENDED USE 4 3 TECHNICAL DATA 4 4 CONNECTION AND COMMISSIONING 5 5 FAULTS PO...

Страница 2: ...ance with European market requirements and may need adapting to the market requirements of the country in question When working at the product observe the following Do not make any changes to the product WARNING Impermissible high load Stop the product immediately after impermissible loading e g impact heat overvoltage Electrical voltage and current DANGER Electrical voltage Regularly check the el...

Страница 3: ...l packaging Secure during transport The vibration values temperature and climate ranges should not be exceeded during transport Storage Store the product in a dry and clean environment that is well protected Ensure that the storage temperature is adhered to see Chapter 3 Technical Data If the product is not operated for a longer period of time we recommend running it for approx 15 minutes annually...

Страница 4: ...rtially dismantled or manipulated protective equipment Operating the product under conditions other than those mentioned in the technical data Furthermore all fields of application not mentioned under intended use An in situ assessment must be conducted of the heating behavior appropriate and inappropriate operation the protection against contact electrical shocks impact of foreign objects or wate...

Страница 5: ... affect the system integration of the product due to interaction Ensure the electromagnetic compatibility of the entire system Voltage control Speed control via the supply voltage is only permitted within the stipulated supply voltage range Speed control via PWM of the supply voltage is not permitted Requirements Before connecting the product ensure that the supply voltage corresponds with the pro...

Страница 6: ... wires Visual inspection min 1 2 yearly Fixation of protective earth connection Visual inspection min 1 2 yearly Insulation of wires Visual inspection min 1 2 yearly Check impeller for wear sediments corrosion Visual inspection min 1 2 yearly 6 COMPLIANCE The product bears the CE mark The CE mark is affixed to adequately sized nameplates Within the meaning of the EMC Guideline 2014 30 EU this docu...

Страница 7: ......

Отзывы: