Operating instructions
S3G500-ZQ12-90
Translation of the original operating instructions
Impeller not
running smoothly
Imbalance in rotating
parts
Clean the device;
replace it if imbalance
persists after cleaning.
Make sure no
weight clips are
removed during
cleaning.
Motor not turning
Mechanical blockage
Switch off, isolate
from supply and
remove mechanical
blockage.
Line voltage faulty
Check line voltage,
restore power supply.
Attention! The error
message resets
automatically.
Device restarts
automatically without
warning.
Faulty connection
Isolate from supply,
correct connection;
see connection
diagram.
Broken motor winding Replace device
Deficient cooling
Improve cooling. Let
the device cool down.
To reset the error
message, switch off
the line voltage for at
least 25 s and then
switch it on again.
Alternatively, reset
the error message by
applying a control
signal of < 0.5 V to
Din1 or by shorting
Din1 to GND.
Ambient temperature
too high
Reduce the ambient
temperature. Let the
device cool down.
To reset the error
message, switch off
the line voltage for at
least 25 s and then
switch it on again.
Alternatively, reset
the error message by
applying a control
signal of < 0.5 V to
Din1 or by shorting
Din1 to GND.
Impermissible point of
operation (e.g. back
pressure too high)
Correct the operating
point. Let the device
cool down.
To reset the error
message, switch off
the line voltage for at
least 25 s and then
switch it on again.
Alternatively, reset
the error message by
applying a control
signal of < 0.5 V to
Din1 or by shorting
Din1 to GND.
In the event of further malfunctions, contact ebm-papst.
6.1 Warning/status codes
The LED on the electronics housing shows the motor status with various
colors and flash codes. The flash codes have a frequency of 2 Hz.
Each flash code is followed by a pause lasting 3 seconds. The following
colors are used: Green: no warning or fault. Orange: There is a warning.
No user intervention is required for warnings. Red: There is at least one
error. See the following table. If there are multiple simultaneous errors,
their associated flash codes are displayed in succession. If there are
simultaneous warnings and errors, only the errors are displayed.
6.1.1 Warning codes
Number of pulses
Motor status - LED
orange
Message at status
relay
1
Current limitation in
action
2
Line impedance too
high (DC-link voltage
unstable)
3
Power limiter in action
4
Output stage
temperature high
5
Motor temperature high
6
Temperature inside
electronics high
7
DC-link voltage low
8
Braking mode: set in
case of external drive
in opposite direction
at high speed for
lengthy period
Yes
9
Calibration of rotor
position sensor in
progress
10
Actual speed is lower
than run monitoring
speed limit
Yes
11
Open circuit at analog
input or PWM input
for the set value
Yes
13
DC-link voltage high
15
Line voltage high
16
Shake-loose function
activated
Item no. 57679-5-9970 · ENU · Change 231171 · Approved 2021-09-15 · Page 15 / 17