Ebird VLCD-5 Скачать руководство пользователя страница 5

 

www.ebikekit.ch 

 

Function Description 

 

4.1、  Speed display  

Show current speed, unit Km/h and mile/h can be chosen. 

4.2、  Energy indicator 

Four horizontal blocks show energy of battery (each block, 25 percents of electric energy), flickering to 

remind you to charge the battery.

  

4.3、  

T

rip distan

ce(reset while power off 

)

 

Show trip distance.

 

4.4、  Odograph 

Show total miles

4.5、  Record movement time ) 

    

Record time while sensor get signal. 

4.6、  (Average speed(AVG)) 
        

Show average speed.

 

4.7、  Power assist 

    

Show power assist.4 levels power assist adjustable.

 

4.8、  Backlight 

Switch among 2 levels brightness, default option is backlight off. 

4.9、  Select wheel-diameter 

Select wheel-diameter among14-32 inch. default option is 26-inch. 

4.10、 Magnetic Steel number  

Select the magnetic steel number of the speed sensor, default value is 1. 

4.11、 Speed  

Select 

Km/h or Mil/h

, default is Km/h. 

4.12、 Function aux. Speed 

Select function of 6km, default value is OFF.

 

4.13、 Select Top Speed 

Select top speed from 15-45 Km/h .Default is 25Km/h. 

4.14、 Power adjustment 

For TSDZ2 = 16. 

Select power adjustment, default is 16. 

4.15、 Language Selection 

Select mode

default is Europe. Do not change! 

4.16、 25speedlimit activation

 

Select function of 25km, default value is ON.

 

4.17、 Diagnostic code 

According  to  the  failure  condition,  the  diagnosis  codes  will  be  displayed.  The  fault  detection  will  be 

launched automatically when rotating the handle and it will stop when the handle is reset. 

 

 

 

 

 

Содержание VLCD-5

Страница 1: ...VLCD 5 VLCD 5 Display Instrument Operation Manual...

Страница 2: ...1 Specification 1 Installation 2 Function Description 3 Operation Flow 4 5 1 Button Definition 4 5 2 Operation and setting 4 5 3 Accessorial function 5 5 4 Hiding function and show 6 5 5 Failure code...

Страница 3: ...peed of electric bicycle record the trip distance Specification Type VLCD 5 Working voltage DC 11V 60V Max working current 70mA 11V 32mA 50V Display type 21 4 21 4 segment LCD sampling 1 12 1 12 pulse...

Страница 4: ...h male and operate on the 4 pin plug female On the plug 1 Orange RX 2 Brown TX 3 White Weak current 4 Green Power 5 Black Earth 6 Purple Brake VLCD wire system VLCD 5 controller 4 core push male Mater...

Страница 5: ...4 9 Select wheel diameter Select wheel diameter among14 32 inch default option is 26 inch 4 10 Magnetic Steel number Select the magnetic steel number of the speed sensor default value is 1 4 11 Speed...

Страница 6: ...minutes 2 OFF ECO TOUR SPEED TURBO 5 ECO There are 4 levels of power assist none low medium high Press this button to adjust the power assist from low to high Default is medium assist ECO TOUR SPEED T...

Страница 7: ...dograph ODO Under the condition of in odometer press the three buttons at the same time for 2s and the odograph reset Odometer Trip distance TRIP In the trip distance state press the button 2s Reset c...

Страница 8: ...n startup screen then all the items including normal functions and special functions shows up Then wait for about a second until the screen changes Then go quickly through the modes menue steps There...

Страница 9: ...The number represents one turn of the wheel the pulse signal output Magnetic steel number selection Speed units selection km h mil h Use the button to enter the speed units interface press button to s...

Страница 10: ...admustment selectin not available yet Use the button to enter the power adjustment selection press or buttons to switch between 6 35 Default is 25 This function not available reserved for next version...

Страница 11: ...ition the diagnosis codes will be displayed The fault detection will be launched automatically when rotating the handle and it will stop when the handle is reset ERR 02 Motor hall fault or motor short...