Main menu: Settings
WiFi
Select network
WPS
Reset account
Displays the selected
network and connection
status.
Wireless Protected Setup
Restores connection to
the app.
Time & date
Set the time
and date.
For WiFi: set the time
zone.
Language
Set the
desired lan-
guage.
Swedish
English
Norwegian
Finnish
German
Screen saver
Screen saver
with three dif-
ferent styles.
Preset Time & Temp.
Adjustable Time & Date
None (off)
Keypad lock
On/Off
Preset to Off
Summer time
On/Off
Preset to On adjusts the
clock automatically for
summer time.
Main menu: Fitter
System info
Displays the
settings and
calibrations.
Sensors
Calibration
Room sen-
sor
If required
Features
Adaptive
function
On/Off (preset On)
Ventilation
function
On/Off (preset On)
Reset
Reset all
Save data
Saving energy
consumption. Other
settings will be reset.
Operating information
Right now
Display of the
current temp.
Room
After X:XX
(time in
hours until
setpoint is
reached)
Set
Set point reached.
Ventilation
The ventilation function switches
off the heat for 15 minutes if it
detects that the temperature
drops by more than three de-
grees in less than one minute.
Circle
Green
Red
Heating ON
Heating OFF
Operating information
The thermostat display displays operational information.
Technical facts
Connection voltage 230 VAC ±10% 50-60 Hz
Setting range
+5°C to +35°C
Power reserve
36 hrs, date and time
Colour
White RAL 9003
Enclosure class
IP24
Approval
CE, S
When a fault occurs, the thermostat switches off the heat-
ing. The display will then display an error code.
Error codes
E1 Short circuit room sensor.
E2 Interruption room sensor