18
Sensor
Conn A (Temp)
Sensor
Conn B (Temp)
Sensor
Conn A & B (Temp)
Sensor Conn C
24 V/DC (moisture)
Clarification
Temp. range:
(factory setting)
Remote control
2
Heat
x
Room
1
x
Floor
1
x
Room & floor
1
-
In Room & floor, the
room is the regulator
and the flooring is the
overheating protec-
tion.
Set pt. +5 °C » +45 °C
(+22 °C)
OH. +5 °C » +45 °C (+35 °C)
x
Vacation, low-temperatu-
re. +5 °C » +20 °C (+12 °C)
Hotel, low temp. +5 °C
» +20 °C (+15 °C), (high
temp. +25 °C), +heat 0-4
hrs (2 hrs)
Cooling
x
Room
1
x
Room
1
-
-
Max. 1 sensor
Set pt. +5 °C » +45 °C
(+22 °C)
x
Vacation, low-temperatu-
re. +20 °C » +40 °C (+27 °C)
Industry
x
Low temp.
1
x
High temp.
1
-
-
Max. 1 sensor
Low -15 °C » +75 °C (+40 °C)
High +0 °C » +170 °C
(+100 °C)
Max/Min
x
Sensor A
1
(A: within temp.
range)
-
x
Sensor A & B
1
(A & B: within
temp. range)
x
Moisture/No
moisture
1
Humidity control (C)
combined with max. 1
temp. sensor, conn. to
input (A).
Max -9 °C » +10 °C (+2 °C)
Min -20 °C » +9 °C (-10 °C)
Overview
1
Shown on the display
O
pe
ra
ti
on
m
ode