background image

- ENGLISH -

 

 

Programming - preset programs 
The thermostat has two built-in temperature setback programs which are 
suitable for the home or office environment. 
 
Program for the home environment. The temperature is reduced 
automatically by 5 degrees C at the following times: 
Mon - Fri 08:30 - 15:00 
Mon - Sun 23:00 - 05:00

 

 

Program for the office environment. The temperature is reduced 

automatically by 5 degrees C all the time except:  
Mon - Fri 05:00 - 18:00

 

 

 
The temperature setback program is chosen as follows (Fig 9): 

press the knob once  

- turn, 

choose 

PROGRAM SELECT

 and press 

turn, choose the desired function 

HOME

/

OFFICE

/

USER

 

(home, office or user) and press. 

 
Programming - user settings 
EB-Therm 300 also has programs for user settings. You can set four events 
during Monday to Friday and two events during Saturday and Sunday. If the 
required temperature is changed manually when a function is active, the 
program resumes operating after the setting at the next event. This is how 
to do user settings (Fig 10): 

press the knob once  

- turn, 

choose 

SETTINGS

 and press 

- turn, 

choose 

SET USER PROGRAM

 and press 

turn, choose period 

4

EV M

-

F

 for Mon-Fri or 

2

EV W

-

E

 

for 

Sat-Sun 

set time and required temperature 

TIME

/

TEMP

 when each 

event is to begin, by turning and pressing the knob.  

 
Display 
The display contrast can be set to suit individual preference as follows (Fig 
11):            

press the knob once      

- turn, 

choose 

DISPLAY

 and press 

- turn, 

choose 

SET CONTRAST 

and press  

set the required contrast by turning the knob, then press. 

  
Time and date – This function shows the current time and date on the 
display as follows (Fig 12): 

press the knob once  

- turn, 

choose 

DISPLAY

 and press 

- turn, 

choose 

SHOW DATE

/

TIME

 and press.  

 

Current settings – This function shows the current settings on the display as 
follows (Fig 13): 

press the knob once  

- turn, 

choose 

DISPLAY

 and press 

- turn, 

choose 

SHOW USER PROG

and press 

- turn, 

choose 

4

EV M

-

F

 (four events) or 

2

EV W

-

E

 

(two 

events) and press 

turn the knob to show each event with the set date and 
temperature, 

SHOW PROGRAM

.

 

press the knob once to return to the previous menu. 

 
Power on/off   
This function put the underfloor heating system in standby mode. It is 
activated as follows (Fig 14): 

press the knob and keep it pressed for about four seconds 

 
Locking function    
This is how to lock the chosen temperature and other settings (Fig 15): 

press the knob once   

- turn, 

choose 

LOCK

 

and press 

- turn, 

choose 

LOCK

 

and press   

a key which locks the temperature appears on the display with 
thermometer 

This is how to unlock the temperature settings (Fig 16): 

press the knob and keep it pressed 

turn the knob clockwise until the key disappears 

 

 
 

 
 

Fault message  

This function indicated when faults have occurred. When faults occur, the 
thermostat contact opens and the LED starts to flash alternately green-red. 
You can also read the nature of the fault by using the diagnostic display of 
the thermostat, as shown in Figure 17. 

press the knob once  

- turn, 

choose 

DISPLAY

 and press 

- turn, 

choose 

DIAGNOSTICS

 and press  

 
 
The diagnostic display shows the status of the sensors. Description of the 
diagnostic display:  

a

 – floor sensor  

b

 – room sensor 

c

 – internal sensor 

d

 – sensor working properly 

e

 – sensor not working – open circuit 

– sensor not working – short circuit 

 
 
 
If a fault is indicated on sensor (b) or (c), replace the thermostat. If a fault is 
indicated on sensor (a), replace the floor sensor. If the floor sensor (a) is 
faulty, the thermostat can only work as a room thermostat, and only if the 
user changes the thermostat function from floor or floor/room thermostat to 
room thermostat. If a sensor is damaged or open circuit, the thermostat 
contact opens, the LED starts to flash (twice a second) and a fault message 
is displayed. If the floor sensor is faulty it must be replaced. If the room 
sensor is faulty, the thermostat must be replaced.  

 

 
 
 

Technical data 

Voltage 

  230 VAC±10% 50-60Hz 

Air temperature range  

 

+5°C to +37°C 

Floor temperature range  

  +5°C to +37°C 

Temperature limiter  

  +5°C to +45°C 

Breaking capacity 

  250 V 16 A 

Connecting cable 

  max 2.5 mm² 

Load  

  Cos 

φ

 = 0.3 max 

Hysteresis  

  ±0.5°C 

Ambient temperature 

  0°C to +60°C  

Degree of protection 

  IP21 

 

Running reserve* 

  12 hours 

Colour  

Polar 

white 

Max. length of sensor cable  

  50m, 2x1.5mm² 

Graphical LCD display  

  96x24 dots 

Indication:  

 

230 V supply connected 

  Green LED 

Heating cable operating 

  Red LED

 

 
Suitable for Eljo Trend, Elko RS, Strömfors and Merten frame systems. 
EMC certified. Withstands a surge of 2500 V AC. 

 
* Time the programmed settings are preserved in the thermostat in the event of power failure, for 

instance 
 

EB-Therm 300 with accessories

 

Art. no. 

Article 

Dimensions (mm) 

E 85 816 65 

EB-Therm 300* 

81x81x40 

E 85 816 68 

Distance frame 

81x81x18 

E 85 816 71 

Sensor cable* 

3 m 

21 066 48        

Front cover for Eljo Trend* 

21 066 51        

Front cover for Eljo RS*    

21 066 57 

IP21 gasket*    

66 210 54 

Frame for Eljo Trend*    

66 210 56 

Frame for Strömfors*    

14 408 80 

Terminal*    

E 85 816 76 

Front cover, aluminium    

E 85 816 77 

Front cover, bronze

 

 

*Included in the pack 

 