- ENGLISH -
Programming - preset programs
The thermostat has two built-in temperature setback programs which are
suitable for the home or office environment.
Program for the home environment. The temperature is reduced
automatically by 5 degrees C at the following times:
Mon - Fri 08:30 - 15:00
Mon - Sun 23:00 - 05:00
Program for the office environment. The temperature is reduced
automatically by 5 degrees C all the time except:
Mon - Fri 05:00 - 18:00
The temperature setback program is chosen as follows (Fig 9):
-
press the knob once
- turn,
choose
PROGRAM SELECT
and press
-
turn, choose the desired function
HOME
/
OFFICE
/
USER
(home, office or user) and press.
Programming - user settings
EB-Therm 300 also has programs for user settings. You can set four events
during Monday to Friday and two events during Saturday and Sunday. If the
required temperature is changed manually when a function is active, the
program resumes operating after the setting at the next event. This is how
to do user settings (Fig 10):
-
press the knob once
- turn,
choose
SETTINGS
and press
- turn,
choose
SET USER PROGRAM
and press
-
turn, choose period
4
EV M
-
F
for Mon-Fri or
2
EV W
-
E
for
Sat-Sun
-
set time and required temperature
TIME
/
TEMP
when each
event is to begin, by turning and pressing the knob.
Display
The display contrast can be set to suit individual preference as follows (Fig
11):
-
press the knob once
- turn,
choose
DISPLAY
and press
- turn,
choose
SET CONTRAST
and press
-
set the required contrast by turning the knob, then press.
Time and date – This function shows the current time and date on the
display as follows (Fig 12):
-
press the knob once
- turn,
choose
DISPLAY
and press
- turn,
choose
SHOW DATE
/
TIME
and press.
Current settings – This function shows the current settings on the display as
follows (Fig 13):
-
press the knob once
- turn,
choose
DISPLAY
and press
- turn,
choose
SHOW USER PROG
.
and press
- turn,
choose
4
EV M
-
F
(four events) or
2
EV W
-
E
(two
events) and press
-
turn the knob to show each event with the set date and
temperature,
SHOW PROGRAM
.
-
press the knob once to return to the previous menu.
Power on/off
This function put the underfloor heating system in standby mode. It is
activated as follows (Fig 14):
-
press the knob and keep it pressed for about four seconds
Locking function
This is how to lock the chosen temperature and other settings (Fig 15):
-
press the knob once
- turn,
choose
LOCK
and press
- turn,
choose
LOCK
and press
-
a key which locks the temperature appears on the display with
thermometer
This is how to unlock the temperature settings (Fig 16):
-
press the knob and keep it pressed
-
turn the knob clockwise until the key disappears
Fault message
This function indicated when faults have occurred. When faults occur, the
thermostat contact opens and the LED starts to flash alternately green-red.
You can also read the nature of the fault by using the diagnostic display of
the thermostat, as shown in Figure 17.
-
press the knob once
- turn,
choose
DISPLAY
and press
- turn,
choose
DIAGNOSTICS
and press
The diagnostic display shows the status of the sensors. Description of the
diagnostic display:
a
– floor sensor
b
– room sensor
c
– internal sensor
d
– sensor working properly
e
– sensor not working – open circuit
f
– sensor not working – short circuit
If a fault is indicated on sensor (b) or (c), replace the thermostat. If a fault is
indicated on sensor (a), replace the floor sensor. If the floor sensor (a) is
faulty, the thermostat can only work as a room thermostat, and only if the
user changes the thermostat function from floor or floor/room thermostat to
room thermostat. If a sensor is damaged or open circuit, the thermostat
contact opens, the LED starts to flash (twice a second) and a fault message
is displayed. If the floor sensor is faulty it must be replaced. If the room
sensor is faulty, the thermostat must be replaced.
Technical data
Voltage
230 VAC±10% 50-60Hz
Air temperature range
+5°C to +37°C
Floor temperature range
+5°C to +37°C
Temperature limiter
+5°C to +45°C
Breaking capacity
250 V 16 A
Connecting cable
max 2.5 mm²
Load
Cos
φ
= 0.3 max
Hysteresis
±0.5°C
Ambient temperature
0°C to +60°C
Degree of protection
IP21
Running reserve*
12 hours
Colour
Polar
white
Max. length of sensor cable
50m, 2x1.5mm²
Graphical LCD display
96x24 dots
Indication:
230 V supply connected
Green LED
Heating cable operating
Red LED
Suitable for Eljo Trend, Elko RS, Strömfors and Merten frame systems.
EMC certified. Withstands a surge of 2500 V AC.
* Time the programmed settings are preserved in the thermostat in the event of power failure, for
instance
EB-Therm 300 with accessories
Art. no.
Article
Dimensions (mm)
E 85 816 65
EB-Therm 300*
81x81x40
E 85 816 68
Distance frame
81x81x18
E 85 816 71
Sensor cable*
3 m
21 066 48
Front cover for Eljo Trend*
21 066 51
Front cover for Eljo RS*
21 066 57
IP21 gasket*
66 210 54
Frame for Eljo Trend*
66 210 56
Frame for Strömfors*
14 408 80
Terminal*
E 85 816 76
Front cover, aluminium
E 85 816 77
Front cover, bronze
*Included in the pack
a
b
c
d
e
f