EBARA Oil Smart Pump System

1. Inspection: Your system has been carefully packaged to prevent damage during  

    shipping. However, occasional damage does occur due to rough handling. Carefully  
    inspect all parts of the system that could cause it to fail. 

2. Refer to the pump installation instructions on page 9 to begin. After completing the  

    pump installation steps, continue here.  

3. Caution: To maintain the NEMA 4X rating, make all wiring connections with seal tight  

    cable grips or conduit connections to be supplied by end user.  

4.  Determine mounting location for control panel. Mount panel using mounting feet supplied.  
5.  Determine hole location on panel for liquid-tight or conduit connections. Attach connectors  

    and conduits. 

6. It is important that the alarm circuit is independent of the pump to assure that the  

    alarm will activate if pump circuit fails. 

7. Run pump cable, Liquid Smart® cable, and Oil Smart® cable through conduit. Make  

    field connections as shown on wiring diagram (See page XX). 

8. Run power line conductor through conduit. Wire to terminals per enclose schematic.  

    Branch circuit protection to be provided by end-user. 

9. For 1-1/2‰ pipe: Attach the Oil Smart® Pump Switch and Oil Smart® Liquid Alarm  

    Switch to the Quick Mount Brackets using the screws and nuts provided. Snap the  
    pump switch bracket onto the discharge pipe with the end of the long sensor 2‰  
    above the top of the pump. Snap the alarm bracket onto the discharge pipe with sensor  
    end 2‰ above the pump switch „on‰ position. Place hose clamps under the quick  
    mount brackets as a reference locator for the switch. Mount switches clear of the  
    basin inlet, so they will stay clean. Note: Keep sensors 1‰ to 2‰ away from any metallic  
    material. 

10.    For other than 1-1/2‰ pipe: Attach the Oil Smart® Pump Switch and Oil Smart®  

    Liquid Alarm Switch to the universal bracket. Place the supplied hose clamp through  
    the slots in the bracket before mounting the switch with the screws and nuts provided.  
    Clamp the Oil Smart® Pump Switch to the discharge pipe with the end of the long  
    sensor 2‰ above the top of the pump. Attach the Oil Smart® Liquid Alarm Switch onto  
    the discharge pipe with the sensor end 2‰ above the pump switch „on‰ position.  
    Mount switches clear of the basin inlet, so they will stay clean. Note: Keep sensors 1‰  
    to 2‰ away from any metallic material. 

 
Start up: 
1. When the power is applied, the red power light locate on the white front swing panel  

    shall light. 

2. The Pump HOA Switch shall be placed to the A (auto) position to ensure the system  

    will pump. The pump can be tested or turned on manually if the HOA switch is in the H  
    (Hand-Manual) position. 

 
To test the alarm circuit, push the test button on the front panel, the audible alarm shall 
sound and the high red beacon will light. 
 
Service: 
Caution: Before checking electrical connections within the control or attempting to replace 
any components, turn off all branch circuits supplying power to the main control panel.

Oil Smart

®

 Pump System – Installation Instructions

Содержание Oil Smart ESS100

Страница 1: ...EBARA Pumps Americas Corporation Operating Instructions Installation Maintenance Manual Note UL and CSA listed Model Optima UL certified only Model ESS100 ESSIM30 ESSIMTP3 Oil Smart Pump System...

Страница 2: ...our supplier supplying dealer or contractor if service is necessary or if you have any questions or need further assistance Please retain the following information for your records and to help expedit...

Страница 3: ...clog the suction strainer plate leading to dry running and subsequent failure Note Pumping sand gravel and other hard debris will shorten the life of the pump Elevate the pump with bricks or other sup...

Страница 4: ...ommonly specified are clay tile fiberglass steel concrete and polyethylene It may be necessary to cut a hole in the basement floor and excavate for the sump Plumbing and electrical contractors could a...

Страница 5: ...low into the pit Sump pumps are not designed to handle raw sewage Do not attempt to adapt one for this type of application A sewage ejector pump especially designed to handle solids must be used Pump...

Страница 6: ...such that all water flows into the basin due to gravity Outdoor installations should be at a sufficient depth to ensure protection from freezing Maintenance Tips Every three or four months 1 Clean th...

Страница 7: ...ch in line check valve to discharge pipe 12 to 18 above pump discharge with arrow pointing away from the pump with the flow Connect other end of check valve securely to drain pipe and tighten clamps N...

Страница 8: ...age at motor causing blown fuses tripping of motor overload or burned out motor 4 Do not connect pump to a power supply until permanently grounded For maximum safety ground pump to a circuit equipped...

Страница 9: ...piece of PVC pipe to adaptor Use appropriate diameter piping Drill a 1 8 relief hole in the pipe 5 above pump connection This hole prevents pump from air locking Step 3 Clamp Check Valve to top of 15...

Страница 10: ...w pumpsebara com 12 t 803 327 5005 f 803 327 5097 rev 01 14 EBARA Oil Smart Pump System Manual Operation Type Output Three Phase Output 1 2 to 11 2 HP Manual Operation Type Output Single Phase Output...

Страница 11: ...WIRING DIAGRAM Model P707U Output 1 2 to 11 2 HP 2 Cable a Never let the end of the cable contact water b If the cable is extended do not immerse the splice in water c Fasten the cable to the discharg...

Страница 12: ...PA 70 Connection devices shall provide for a watertight connection to the power supply and provide adequate strain relief for the cord Installation of the box shall be a Listed watertight connection b...

Страница 13: ...t hole in pump case Vertical pumping distance is too high Reduce distance or resize pump Inlet holes in pump base are clogged Remove pump and clean the openings Impeller or volute openings is fully or...

Страница 14: ...it breaker or unscrew fuse Cleaning impeller and volute case Remove screws that hold lower base to housing CAUTION Do not remove motor housing or unscrew impeller Use screwdriver to pry base from hous...

Страница 15: ...n www pumpsebara com 17 t 803 327 5005 f 803 327 5097 rev 01 14 EBARA Oil Smart Pump System Sectional View Optima 3MS1 EPD 3MS1 Manual Type Output Refer to page 29 for Material Details Ground Wire Opt...

Страница 16: ...a l u s n i l a n i m r e T 2 5 1 e l b a c r e w o P 4 5 1 h c t i w S 5 5 2 4 0 3 I S I A 1 0 3 4 1 N E r e c a p S 7 5 1 1 0 3 F G 6 6 A P r o t c e n n o c e l b a c r e w o P 8 5 59 Switch cable...

Страница 17: ...ss AISI 304 1 039 Key 304 Stainless AISI 304 1 048 Impeller Nut 304 Stainless AISI 304 1 set 111 1 Mechanical Seal 1 set 111 2 Mechanical Seal 1 set 120 Connection Band 304 Stainless AISI 304 200 Lift...

Страница 18: ...4 1 048 Impeller Nut 304 Stainless AISI 304 1 set 111 1 Mechanical Seal t e s 1 111 2 Mechanical Seal t e s 1 120 Connection Band 304 Stainless AISI 304 1 200 Lifting Hanger 304 Stainless AISI 304 1 2...

Страница 19: ...20 cord Optional length available up to 100 Indoor Outdoor NEMA 4X Heavy Duty Polycarbonate Enclosure 6 x5 x2 5 Color Gray Material 94V 2 Polycarbonate IP 56 Rating Voltage 120 VAC Single Phase 50 60H...

Страница 20: ...ords and mounting brackets Indoor Outdoor NEMA 4X Heavy Duty Polycarbonate Enclosure 10 x8 x4 Color Gray Material 94V 2 Polycarbonate IP 56 Rating Voltage 120 208 240 VAC Single Phase 50 60Hz CSA Inte...

Страница 21: ...EBARA Pumps Americas Corporation www pumpsebara com 23 t 803 327 5005 f 803 327 5097 rev 01 14 EBARA Oil Smart Pump System Oil Smart Simplex Panel ESSIM30 Wiring Diagram...

Страница 22: ...carbonate IP 56 Rating Voltage 208 240 480 VAC Three Phase operates pumps up to 3HP 208 240V or 7 5HP 480V Multi Tap transformer 208 240 480VAC Primary provides 120V control power for the Smart Board...

Страница 23: ...EBARA Pumps Americas Corporation www pumpsebara com 25 t 803 327 5005 f 803 327 5097 rev 01 14 EBARA Oil Smart Pump System Oil Smart Simplex Panel ESSIMTP3 Wiring Diagram...

Страница 24: ...d of the long sensor 2 above the top of the pump Snap the alarm bracket onto the discharge pipe with sensor end 2 above the pump switch on position Place hose clamps under the quick mount brackets as...

Страница 25: ...bara com 27 t 803 327 5005 f 803 327 5097 rev 01 14 EBARA Oil Smart Pump System ON OFF HIGH LIQUID Liquid Smart Alarm Switch Oil Smart Pump Switch Pump included Oil Smart Alarm Oil Smart Alarm Switch...

Страница 26: ...ers down the off sensor Remove your fingers from off sensor and the pump will turn off Or fill sump with water when water reaches on sensor the pump will turn on and remain on until water clears the o...

Страница 27: ...oil base product kerosene solvent Improper Mounting of Components Keep control 1 to 2 clear of any metallic material Mount to pvc pipe or if mounting to metal pipe make sure to mount with See Water q...

Страница 28: ...mer for the Pump Freight charges for replacement Pumps under this MODEL Optima NO FAULT LIMITED WARRANTY are the responsibility of the Customer To obtain MODEL Optima NO FAULT LIMITED WARRANTY conside...

Страница 29: ...mp EPAC shall be liable only for the cost of the Pump or the cost of repair or replacement of any defective Pump Customer shall be responsible for labor cost of removal and instal lation at Customer s...

Страница 30: ...ration 1651 Cedar Line Drive Rock Hill SC 29730 t 803 327 5005 f 803 327 5097 www pumpsebara com 2018 EBARA Pumps Americas Corporation EOSPS 0114 Contact your dealer or supplier for more information a...

Отзывы: