5
EN
5.1. INSTALLATION
To install the pumps, proceed as directed in PART 1, chapter 7.2
and in the following points:
– use pipes of a suitable diameter, bearing in mind that, in
some models, suction diameter (front side of pump) is great-
er than delivery diameter (top side of pump), (see chap. 4).
5.2. FILLING THE PUMP JE(S)(X) (FIG.1); AG (FIG.2)
WARNING
OPERATION TO BE PERFORMED WITH THE MOTOR’S
TERMINAL STRIP FULLY CLOSED.
a) Unscrew the hexagonal cap (1-2) located on the top of the
pump casing;
b)
With the aid of a funnel, fill the pump with water to over
-
flowing;
c) Screw the hexagonal cap back on until it is locked tight to
prevent air getting in.
5.3. ASSEMBLING AND INSTALLING DOMESTIC WATER
BOOSTER SETS
AGA-AGC-AGE-AGF-series pumps can be supplied ready to ac-
commodate a pressure gauge, pressure switch (to be fastened
to the pump casing) and three-way fitting.
To assemble the set, refer to the specific instruction manual.
6. DIAGRAMS AND DRAWINGS
DECLARATION OF CONFORMITY TO EC DIRECTIVE 2000/14
We, EBARA PUMPS EUROPE S.p.A., via Campo Sportivo, 30 – 38023 CLES (TN) Italy, hereby declare under own responsibility that our products listed in the
table at the foot of the page are in conformity with EC Directive 2000/14 article 13 and internal production control procedure according to appendix V.
Lwa (M): sound power level (A-weighted), measured• Lwa (G): sound power level (A-weighted), guaranteed.
(see table at foot of page).
Mr. SHU NAGATA
President
12 January 2009
GARDEN
JES M5, JES M6, JES M8, JESX M5, JESX M6,
JESX M8, AGE 050M, AGE 060M, AGE 080M,
AGF 060M, AGF 080M, AGF 060M, AGF 080M
JEM 80, JEM 100, JEM 120, JEXM 80, JEXM
100, JEXM 120, AGA 060M, AGA 075M,
AGA 100M
JEM 150,
JEXM 150
Lwa (M)
74 dB/pW
78 dB/pW
83 dB/pW
Lwa (G)
76 dB/pW
80 dB/pW
85 dB/pW