EBARA DMLU Скачать руководство пользователя страница 10

DMLU

Sectional view

Project:

Model:

Chk’d:

Date:

5 to 10 HP
80DML
100DML
150DML

PART

NO.

001

016

021

080

107

111

174

193

211

275

801

802

PART NAME

CASING

MECHANICAL SEAL COVER

IMPELLER

BUSHING

WEARING RING

MECHANICAL SEAL

DISCHARGE PIPE

OIL PLUG

AIRVENT VALVE

IMPELLER BOLT

ROTOR

STATOR

MATERIAL

CAST IRON

CAST IRON

CAST IRON

STEEL

BRONZE

CAST IRON

RUBBER (NBR)

BRASS

STAINLESS STEEL

NO. FOR

1 UNIT

1

1

1

1

1

1

1

1 SET

1

1

1

1

PART

NO.

811-1

811-2

814

816

817

830

849-1

849-2

856

904

907

PART NAME

SUBMERSIBLE CABLE (POWER)

SUBMERSIBLE CABLE (SIGNAL)

MOTOR FRAME

POWER SIDE BRACKET

OPPOSITE SIDE BRACKET

SHAFT

BALL BEARING

BALL BEARING

THERMAL PROTECTOR

LIFTING HANGER

BEARING COVER

MATERIAL

CAST IRON

CAST IRON

CAST IRON

STAINLESS STEEL

STEEL

STEEL

NO. FOR

1 UNIT

2

1

1

1

1

1

1

1

3

1

1

CALL 1-800-577-8111 FOR SALES AND SUPPORT

CALL 1-800-577-8111 FOR SALES AND SUPPORT

Содержание DMLU

Страница 1: ...Instruction and Operation Manual Model DMLU CALL 1 800 577 8111 FOR SALES AND SUPPORT CALL 1 800 577 8111 FOR SALES AND SUPPORT...

Страница 2: ...and can cause electrical shorts that can possibly lead to fires 3 A qualified electrician should perform all wiring and all national and local electrical codes must be observed 4 Make sure that all e...

Страница 3: ...tions that you ordered Fig 1 Pump Nameplate Specifications Item Liquid handled Type Temperature Solids Capacity Discharge size in Solid size in Materials Impeller Phase Hz Motor Voltage Starting Metho...

Страница 4: ...submerged as it will result in backflow when the pump stops g Set control operating levels i e floats so that pump is not running for more than ten minutes with water level at minimum operating level...

Страница 5: ...ion 2 Check to make sure there is an adequate amount of water in the wet well Continuous operation of the pump in a dry condition will cause the motor protector to be activated 3 Check the direction o...

Страница 6: ...ir may be required 3 Recommended annual inspections a Check the oil in the seal chamber If the oil has turned white it is an indication that water has mixed with the oil and the mechanical seal needs...

Страница 7: ...tween power source and voltage 2 Significant voltage drop 3 There is an open phase 4 Reverse rotation 5 Low head pumping too much liquid 6 Foreign matter clogging pump 7 Motor bearing is worn or damag...

Страница 8: ...mber d Remove the mechanical seal carefully to keep from damaging the seal faces 2 Reassembly a Perform the above instructions in reverse order replacing the o ring seal washer and gasket Note 1 After...

Страница 9: ...TAINLESS STEEL BRONZE CAST IRON RUBBER NBR BRASS STAINLESS STEEL NO FOR 1 UNIT 1 1 1 1 1 1 1 SET 1 SET 1 1 1 1 PART NO 811 814 816 817 830 849 1 849 2 876 904 907 PART NAME SUBMERSIBLE CABLE MOTOR FRA...

Страница 10: ...RONZE CAST IRON RUBBER NBR BRASS STAINLESS STEEL NO FOR 1 UNIT 1 1 1 1 1 1 1 1 SET 1 1 1 1 PART NO 811 1 811 2 814 816 817 830 849 1 849 2 856 904 907 PART NAME SUBMERSIBLE CABLE POWER SUBMERSIBLE CAB...

Страница 11: ...RONZE CAST IRON RUBBER NBR BRASS STAINLESS STEEL NO FOR 1 UNIT 1 1 1 1 1 1 1 1 SET 1 1 1 1 PART NO 811 1 811 2 814 816 817 830 849 1 849 2 856 904 907 PART NAME SUBMERSIBLE CABLE POWER SUBMERSIBLE CAB...

Страница 12: ...pair or replacement of any defective Pump Customer shall be responsible for labor cost of removal and installation at Customer s premises transportation and insurance costs to EIC RH and any other inc...