Installation 

(2) Cable 

     a)  Never let the end of the cable contact water 
     b)  If the cable is extended, do not immerse the splice in  

           water.  

     c)  Install the cable so that it will not overheat.  

           Overheating is caused by coiling the cable and exposing  
           it to direct sunlight. 
(3) Grounding 

     As shown in Fig. 3 ground the green wire (label E).  
     Under no circumstances should the green wire be  
     connected to the power supply. 

(4) Use short circuit breakers to prevent danger of electrical  

     shock. 

 

Operation 

1.   Before starting the pump: 

     (1) After completing installation, measure the insulation resistance again as described in INSTALLATION. 
     (2) Check water level. 
     If the pump is operated continuously for an extended period of time in a dry condition or at the lowest water level, the  
     thermal protector will be activated. 
     Constant repetition of this action will shorten pump service life. Do not start the pump again in such a situation until after  
     the motor has completely cooled. 

 

2.   Test Operation: 

 
 
 
 

     (1) Model DDLFU 

           a)  Turn the operating switch on and off a couple of times to check for normal pump start. 
           b)  Check the direction of rotation. If discharge volume is low or unusual sounds are heard when the pump is operating,  

                rotation has been reversed. When this happens, reverse two of the three wires. 

           c)  Check amperage, voltage, and head pressure. 
 
 
 
 

Maintenance and Service 

 
 
 
 

 

Check pressure, output, voltage, current, vibration, and other specifications. Unusual readings may indicate a problem requiring 
immediate service. Contact your local EBARA PUMPS AMERICAS CORPORATION representative as soon as possible.

CAUTION 

Check rotation. Correct rotation is clockwise when viewed from top of motor. Pump should be started with gate valve 
closed, and then the operator should open the valve gradually.

Fig. 3

WARNING 

Disconnect power cable from power source before servicing unit. 

Normal maintenance should be done by qualified personnel.

Содержание DDLFU

Страница 1: ...Submersible Dry Pit Non clog Water Wastewater Pump Model DDLFU Model DDLFMU Operating Instructions Installation Maintenance Manual EBARA Pumps Americas Corporation...

Страница 2: ...ion WARNING Before handling this pump always disconnect the power first Do not use sparkable electrical devices or flames in a septic gaseous or possible septic sump Do not work under heavy suspended...

Страница 3: ...hly by hand 2 Precautions when operation is suspended 1 If operation is to be suspended for 30 days with the pump immersed in water measure the insulation resistance of the motor If resistance is over...

Страница 4: ...evelop 5 Do no operate the pump for a long time with the water level near the minimum operating level as the automatic cut off switch incorporated inside the motor will be activated To avoid dry opera...

Страница 5: ...the pump Make sure all electrical connections are secure Output 15 to 30HP 208 230V 460V WARNING Check that the power is locked off and disconnected before working on pump All electrical work should b...

Страница 6: ...pumpsebara com 6 803 327 5005 803 327 5097 fax rev 04 19 Output 40 to 60HP 208 230V 460V G GRN L1 RED T1 T7 L2 WHT T2 T8 L3 BLK T3 T9 L5 WHT T4 T10 L6 BLK T5 T11 L4 RED T6 T12 P1 RED P2 WHT P3 BLK P4...

Страница 7: ...otector will be activated Constant repetition of this action will shorten pump service life Do not start the pump again in such a situation until after the motor has completely cooled 2 Test Operation...

Страница 8: ...ive mechanical seal requiring replacement The service life of the mechanical seal can be prolonged by replacing the oil in the mechanical seal chamber once a year When replacing the oil lay the pump o...

Страница 9: ...e has activated motor protector 2 Lower liquid temperature and caused pump to stop Does not pump 1 Reverse rotation 1 Correct rotation see Operation 2 3 Inadequate volume 2 Significant drop in voltage...

Страница 10: ...6 3 6 6 PART NO 120 11 125 167 174 193 1 193 2 193 3 193 4 193 5 193 6 200 801 802 811 1 811 2 814 816 1 816 2 817 830 831 838 1 838 2 849 1 849 2 876 909 924 1 924 2 PART NAME BOLT BOLT SUCTION ELBOW...

Страница 11: ...8 8 4 6 6 3 8 8 PART NO 120 10 125 167 174 193 1 193 2 193 3 193 4 193 5 193 6 200 801 802 811 1 811 2 814 816 1 816 2 817 830 831 838 1 838 2 849 1 849 2 876 909 924 1 924 2 PART NAME BOLT BOLT SUCT...

Страница 12: ...304 AISI304 NO FOR 1 UNIT 1 1 1 1 1 1 1 1 SET 1 1 1 1 1 1 1 1 2 1 1 1 2 12 4 8 4 8 8 4 6 PART NO 120 10 120 11 125 167 174 193 1 193 2 193 3 193 4 193 5 200 801 802 811 1 811 2 814 816 1 816 2 817 830...

Страница 13: ...AISI304 AISI304 AISI304 AISI304 NO FOR 1 UNIT 1 1 1 1 1 1 1 SET 1 1 1 1 1 1 1 1 2 1 1 1 12 4 8 4 8 4 8 6 8 PART NO 120 10 125 167 174 193 1 193 2 193 3 193 4 200 801 802 811 1 811 2 814 816 1 816 2 8...

Страница 14: ...MTP which are embedded in the windings When temperature of the winding raises and reaches the MTP acting point the motor protection circuit is activated to protect motor from over heat 1 Applicable mo...

Страница 15: ...ry reed switch encapsulated within a stem The switch opens on rise of liquid 2 Specifications Apply to 2 to 30HP Breaking Capacity AC50VA DC50W Max Breaking Current AC0 5A DC0 5A Max Operating Voltage...

Страница 16: ...rtation shall be borne by the Purchaser No allowance will be made for repairs without EPAC s written consent or approval and the Warranty Period shall not be suspended upon stopping operation for warr...

Страница 17: ...re information about other EBARA products EBARA Pumps Americas Corporation 1651 Cedar Line Drive Rock Hill SC 29730 803 327 5005 t 803 327 5097 f www pumpsebara com 2018 EBARA Pumps Americas Corporati...

Отзывы: