EVMS/EVMSL
- 8 -
*5 In the case of inverter drive, be careful of the following points, and discuss the situation with the
manufacturer of the inverter used.
(1)
Ensure that the motor’s operating output is 90% or less of the rated output.
(2) Set the output frequency range at 60 to 95% of the mains power frequency.
(3) With inverter drive, magneto-sonic waves are produced by the motor, which may sound
quite harsh in comparison with mains power drive.
(4) Avoid a rotational speed range in which the pump and motor resonate during normal
operation.
*6 0.75 kW or higher models is cleared the Top Runner Standards.
*7 0.55 kW or less models is equivalent to premium efficiency (EBARA own setting).
■
Optional specifications
Different
rubber material
NBR (Liquid temperature : 0
℃~
60
℃
),
EPDM
Different
mechanical seal
SiC/SiC type (Liquid temperature : 0
℃~
90
℃
)
Purified water type (Liquid temperature : 25±5
℃)
Different
motor
Different voltage
・
Special different voltage
Terminal box position change (every 90
)
Tropical treatment, Anticorrosion treatment
Painting in designated color
Pull out the stage (1
~
2 stage)
Oil free treatment
■
Table 1
Minimum flow (L/min)
50Hz
Flooding or positive suction
When sucking
Size
Liquid temperature :
~
80
℃
*1
More than 81
℃
~
40
℃
More than 41
℃
25S
2
12
12
Unusable
25
3
20
20
32
5 *2
40
40
40
7
75
75
50
11 *2
130
130
50L
14 *2
180
180
60Hz
Flooding or positive suction
When sucking
Size
Liquid temperature :
~
80
℃
*1
More than 81
℃
~
40
℃
More than 41
℃
25S
3
13
13
Unusable
25
3
25
25
32
5 *2
50
50
40
8 *2
90
90
50
14 *2
170
170
50L
14
220
220
Note) *1 : Please avoid continuous operation, this value is applied in temporary operation.
*2 :
But following models is equivalent to value of More than 81
℃
.
50Hz : 32EVMS(L)2755.5
・
50EVMS(L)17515
・
50EVMS(L)16518
:
60Hz : 32EVMS(L)1967.5
・
40EVMS(L)16611
・
50EVMS(L)12618