Page 8 of 8 

Drawing   : - TPC406 
Issue 

: - 3 

Date 

: - 08/08/14 

 
 

RM85 

SPARE PARTS LIST 

    

    

    

    

 

N

UMBER

 

D

ESCRIPTION

 

P

ART 

N

UMBER

 

Q

UANTITY

 

Timer 

1619508 

Condenser coil 

2029322 

Evaporator coil 

2029323 

Cable & Tube wrap 

2056002 

Drain tray 

2056003 

Filter 

2056004 

Capillary 

3014254 

2 X 2ft 

Solenoid valve 

3020837 

Filter dryer 

3020909 

10 

Defrost Relay 

3030270 

11 

Solenoid coil 

3030452 

12 

Hour meter 

3030778 

13 

On/Off switch 

3035914 

14 

Power Relay 

3036188 

15 

Run capacitor 

3036337 

16 

Pump purge switch 

3036779 

17 

Fan 

3040278 

18 

Fan inlet ring 

3040283 

19 

Wheel 

3050124 

20 

Rubber foot 

3101436 

21 

Condensate pump 

3160151 

22 

Compressor 

3944933 

 

UK Head Office 

 

Ebac Industrial Products Ltd 

St Helens Trading Estate 

Bishop Auckland 

County Durham 

DL14 9AD 

 

Tel: +44 (0) 1388 664400 

Fax: +44 (0) 1388 662590 

 

www.eipl.co.uk

 

[email protected]

 

 

American Sales Office 

 

Ebac Industrial Products Inc 

700 Thimble Shoals Blvd. 

Suite 109, Newport News 

Virginia, 23606-2575 

USA 

 

Tel: +01 757 873 6800 

Fax: +01 757 873 3632 

 

www.ebacusa.com

 

[email protected]

 

 

 

German Sales Office 

 

Ebac Industrial Products Ltd. 

Gartenfelder Str. 29-37 

Gebäude 35 

D-13599, Berlin 

Germany 

 

Tel: +49 3043 557241 

Fax: +49 3043 557240 

 

www.eip-ltd.de

 

[email protected]

 

 

Содержание RM85 10560RG-GB

Страница 1: ...Page 1 of 8 Drawing TPC406 Issue 3 Date 08 08 14 RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Страница 2: ...air is therefore discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered Continuous circulation of air through the dehumidifier gradua...

Страница 3: ...l GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the pr...

Страница 4: ...i If the air temperature is above 25 C frost and or droplets of condensed water should cover the entire evaporator coil F When the unit is operated in ambient of less than 15 C a defrost cycle should...

Страница 5: ...roplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections including mains c...

Страница 6: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Страница 7: ...fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass va...

Страница 8: ...ch 3036779 1 17 Fan 3040278 1 18 Fan inlet ring 3040283 1 19 Wheel 3050124 2 20 Rubber foot 3101436 2 21 Condensate pump 3160151 1 22 Compressor 3944933 1 UK Head Office Ebac Industrial Products Ltd S...

Отзывы: