CD200 OWNERS MANUAL
Drawing No. :- TPC364
Issue
:- 7
Date
:- 10/12/13
INSTALLATION
POSITIONING:
Position the dehumidifier unit in the center of the room to be conditioned if at all possible.
However if a damp patch is particularly apparent the outlet grille should be pointed towards it if
possible.
This unit can also be used in a duct system where applicable, please see the diagrams on the
following pages which identify the overall sizes of the unit and also the mounting points.
NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have clear space around
them and not be obstructed in anyway.
This unit should be connected to a single outlet circuit fused spur with a 20A rating.
Selecting the correct fan speed – The CD200 has a low fan speed and a high fan speed and the
required speed must be chosen before installation. To select the correct fan speed firstly remove
the filter cover via the 9off screws, then remove the electrical box cover via the 4off M4 hex
head bolts. Once the electrical box cover is removed the supplied link wire must be wired
between either the ‘C’ and ‘L’ or the ‘C’ and ‘H’ terminals on the terminal block. This is shown
below. The default setting of the unit is high speed.