Changing the Bulb
WARNING: Always turn Off the appliance and disconnect from the power supply before
changing the bulb.
1. Remove the collection tray.
2. Lay the appliance face down.
3. Unscrew the two screws
holding the safety guard at
the rear of the Insect killer
[Fig. 1].
1
4. Lift up the guard rail [Fig. 2].
2
5. Holding the ends of the bulb,
twist it ‘forwards’ in its socket
until it clicks [Fig. 3].
3
6. Slide the bulb up out of its
sockets [Fig. 4].
7. Replace with a new bulb.
8. Twist the new bulb
‘backwards’ to lock it back in
place.
9. Replace the guard rail and the
two screws.
4
Troubleshooting
Fault
Probable Cause
Solution
The
appliance is
not working
The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug or lead is damaged
Call EAZYZAP agent or qualified Technician
Power supply
Check power supply
Tube has expired
Refer to the ‘Changing the Bulb’ section
Tube is faulty or has not been fitted correctly
FD496-A-FD497-A-FD498-A_A5_v1_20210611.indb 4