background image

8

LED INDICATORS

8 . 1

E t h e r n e t

The LEDs on the Ethernet connector indicate the Ethernet connection and activity status.

Left Link LED

Status

Right Activity LED

Status

Amber color

10 Mbps

Amber color

Half duplex

Green color

100 Mbps

Green color

Full duplex

On

Link established

On/flashing 

Data activity

Off

No link

Off

No activity

8 . 2

U - N e t   I n d i c a t o r s

The U-Net LEDs on the front/rear panels indicate the U-Net network status.

Green LED (

)

Red/Yellow LEDs (!) Status

On

Off

U-Net network detected

On

Flashing

Local fault: not sending or receiving on the assigned
U-Net channel(s) or local and received sample rates are
not synchronized

On

On (2 seconds)

Local fault detected on another device on the network

Off

Off

No network detected

8 . 3

I n p u t   m e t e r s

The input meters indicate the signal level in dB below 0 dBFS (0 dB Full Scale), the clip level of the ADC
(analog to digital converter). An input meter still functions when its Input Channel is muted. Ideally, the
highest levels of the signal should illuminate the -6 LED segment, but not the CLIP segment. Occasional
flashing of the CLIP segment may be sonically acceptable.

LED Segment

Signal Level

Clip  Red

0 dBFS

- 6    Yellow

-6 dBFS

-12   Green

-12 dBFS

Sig   Green

-40 dBFS

8 . 4

O u t p u t   M e t e r s

Unlike the input meters, the four LED segments of each output meter make up two different meters. 

8

.4.1

SIG, -12, A

N

D CLIP SIG SEGME

N

TS

These three segments monitor the signal level in dB below 0 dBFS (0 dB Full Scale), the clip level of the
DAC (digital to analog converter). An output meter still functions when its Output Channel is muted.
Ideally, you want the highest level to illuminate the -12 segment, but not the CLIP segment. You can set
levels lower than this, but understand that you are reducing the signal-to-noise ratio.

LED Segment

Signal Level

Clip Red

0 dBFS

-12  Green

-12 dBFS

Sig Green

-40 dBFS

8

.4.2

LIM SEGME

N

T

This segment monitors the limiter status referenced to the level set for the limiter threshold. The Lim
segment will indicate limiting even when its Output Channel is muted. 

LED Segment

Status

Lim Yellow

On when the limiter threshold is exceeded and there is gain reduction

Occasional flashing is OK. However, if the LED is rapidly flashing yellow or is on steadily a large
percentage of the time, the input signal to the loudspeaker may be exceeding the loudspeaker’s capability
and the volume level should be reduced.

Page 20

OUTPUT CHANNELS

OUTPUT CHANNELS

Clip

Clip

Lim

-12

-12

Sig

Sig

Clip

Clip

Lim

Lim

-12

-12

Sig

Sig

Clip

Clip

Lim

Lim

-12

-12

Sig

Sig

Clip

Clip

Lim

Lim

-12

-12

Sig

Sig

Clip

Clip

Lim

Lim

-12

-12

Sig

Sig

2

3

4

5

6

ETHERNET

ETHERNET

2

1

U-NET

U-NET

U-NET

1

2

INPUT CHANNELS

INPUT CHANNELS

Clip

Clip

-6

-6

-12

-12

Sig

Sig

Clip

Clip

-6

-6

-12

-12

Sig

Sig

Clip

Clip

-6

-6

-12

-12

Sig

Sig

Clip

Clip

-6

-6

-12

-12

Sig

Sig

A

B

C

D

Содержание UX8800

Страница 1: ...12 12 Sig Sig Clip Clip Lim Lim 12 12 Sig Sig Clip Clip Lim Lim 12 12 Sig Sig Clip Clip Lim Lim 12 12 Sig Sig Clip Clip 6 6 12 12 Sig Sig Clip Clip 6 6 12 12 Sig Sig Clip Clip 6 6 12 12 Sig Sig Clip C...

Страница 2: ...Page ii...

Страница 3: ...must remain accessible to be able to disconnect power from the apparatus 11 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where th...

Страница 4: ...quilat ral pr vient l utilisateur de la r sence d instructions importantes relatives l utilisation et la maintenance du produit dans le manuel fourni avec le produit 1 Lisez ces instructions 2 Conserv...

Страница 5: ...longue avantde causer de tels dommages vitez toute exposition prolong e aux niveaux sonores lev s DANGER Danger d explosion en cas de non remplacement correct de la pile Remplacez uniquement par une...

Страница 6: ...alla pioggia l unit non funziona correttamete oppure caduta 16 Non esporre questa unit a gocce o schizzi di alcun liquido Non posizionare sull unit oggetti contenenti liquido come vasi o bicchieri 17...

Страница 7: ...aja en su salida de corriente p ngase en contacto con un electricista ara que sustituya esa salida obsoleta 10 El enchufe de salida de corriente debe quedar accesible para que pueda desconectar el cab...

Страница 8: ...htung dieser Hinweise k nnen m glicherweise zu Sch den am Equipment oder zu Verletzungen bzw zum Tod von Personen f hren Sollte es Widerspr che oder berlappungen geben mit anderen Produktanleitungen g...

Страница 9: ...ose mit drittem Schutzleiterkontakt 18 Dieses Ger t erf llt die Class A Class B Richtlinien je nachdem elche zutrifft in Bezug auf die Aussendung von St rstrahlung die von digitalen Ger ten ausgehen w...

Страница 10: ...Immunity The Technical Report File is maintained at LOUD Technologies Inc Worldwide Headquarters 16220 Wood Red Road NE Woodinville WA98072 USA Tel 1 425 892 6500 Tel 866 858 5832 Fax 1 425 487 4337...

Страница 11: ...ons 6 5 OPERATION INITIAL SETUP 9 5 1 Power On Off 9 5 2 Front Panel Controls 9 5 3 UTIL System Set Up 10 6 OPERATION SYSTEM PROCESSOR MODE 12 6 1 Introduction 12 6 2 Select System Processor Mode 12 6...

Страница 12: ...ing Damage If you find the processor is damaged after unpacking save the packing materials for the carrier s inspection notify the carrier immediately and file a shipping damage claim Although EAW wil...

Страница 13: ...hile providing robust driver protection These preset parameters are locked down to prevent inadvertent or purposeful modifications However the user retains control of gain input EQ signal delay and po...

Страница 14: ...240 V 50 Hz to 60 Hz 13 ac mains fuse 4 A slow blow main and spare in IEC Receptacle drawer 14 Power ac mains on and off 15 Outputs 1 to 8 XLR connectors for audio outputs analog 16 Inputs A to D XLR...

Страница 15: ...in compliance ratings keep the ac mains voltage between 100 V to 240 V 4 2 2 IEC POWER CORD RECEPTACLE An IEC 320 ac mains inlet on the rear panel accepts the detachable power cords supplied with the...

Страница 16: ...el 2 4 3 3 OUTPUT CONNECTIONS The eight male XLR type connectors labeled 1 through 8 are the audio output connectors Analog XLR 1 to XLR 8 Electronically balanced line level Pin 1 shield Pin 2 plus or...

Страница 17: ...cable is required when connecting two Ethernet ports in the same layer of the OSI model Open Systems Interconnection Reference Model A computer s Ethernet port meaning its NIC network interface card a...

Страница 18: ...me U Net cables by assigning Input Channel and Output Channel signals to U Net channels 4 4 8 SOFTWARE INSTALLATION EAWPILOT EAWPilot requires an IBM compatible PC equipped as follows Operating System...

Страница 19: ...ont panel The display can be adjusted for best viewing using the UTIL LCD Contrast function 5 2 2 FUNCTION BUTTONS Use the function buttons to display and edit the operating parameters of the UX8800 C...

Страница 20: ...cessor modes all settings will be reset to the factory default settings for that mode In order to avoid losing any custom settings save them using the PROG function before switching modes During the m...

Страница 21: ...col server Static Manually enter an IP address normally a private IP address The first three number groups in the IP address must be the same for both the computer and the UX8800 For example 192 168 0...

Страница 22: ...h output channel 6 5 1 6 4 CH Input Channels A to D Use the CH function to set the parameters for Input ChannelsAto D by selecting theAto D buttons 6 4 1 SRC SOURCE 1 SOURCE 2 Select either a single s...

Страница 23: ...ressor limiter parameters Lim Sets the Comp Lim to In active or Out inactive Thrsh Scroll through and select the limiter threshold from 20 dBu to 10 dBu in 0 1 dB steps Ratio Scroll through and select...

Страница 24: ...find a destination to save the current processing parameters Name the program to be saved If a memory with an existing program is chosen rename the program to be saved This will replace the existing...

Страница 25: ...iver time alignment polarity gain crossover filters and high low pass filters These settings are fixed at the factory 2 Gunness Focusing This consists of a precise and highly complex filter specifical...

Страница 26: ...s fully user adjustable When set for generic processing the Input Channel processing can be adjusted using the UX8800 front panel However Output Channel processing can only be adjusted using EAWPilot...

Страница 27: ...r or array may be voiced incorrectly be over protected or be under protected 7 5 3 AMP GAIN Scroll through and select the Amp Gain for the amplifier connected to that output channel The range is from...

Страница 28: ...djusting the distance parameter NOTE To bypass theAir Loss Pre emphasis filter set the Listening Dist to 1 m 7 6 LEVEL Input Channels A to D Use the LEVELfunction to set Input Channel gain and polarit...

Страница 29: ...frequency for each filter Variable from 20 Hz to 20 kHz in 1 24th octave steps Gain Scroll through and select the gain for each filter 15 dB in 0 1 dB steps Filt Sets the selected filter 1 to 10 to I...

Страница 30: ...put meter make up two different meters 8 4 1 SIG 12 AND CLIP SIG SEGMENTS These three segments monitor the signal level in dB below 0 dBFS 0 dB Full Scale the clip level of the DAC digital to analog c...

Страница 31: ...so that any changes will affect all such linked parameters 9 1 3 FIRMWARE UPDATE EITHER MODE Using the Settings tab in the UX8800 interface window the firmware program for the UX8800 can be updated 9...

Страница 32: ...onditions that subject the unit to mechanical stress such as part of a portable or touring system 10 2 Service There are no user serviceable parts inside the UX8800 processor In case of failure refer...

Страница 33: ...ted The meters function independently of the mute switch No output and no output meter lights on some or all channels Incorrect configuration Check that the output s is assigned an Input Channel Signa...

Страница 34: ...Polarity Gain Polarity Meter Meter Meter Meter Meter Meter Meter Meter Meter Meter Meter Meter Limiter Limiter Limiter Limiter Limiter Limiter Limiter Limiter Mute Mute Mute Mute Mute Mute Mute Mute U...

Страница 35: ...E MUTE MUTE MUTE MUTE MUTE Preset Gunness Focusing Loudspeaker Processing Sub system Crossover EQ Gain Polarity Limiter Alignment Delay Air Loss Pre emphasis Preset Gunness Focusing Loudspeaker Proces...

Страница 36: ...s However the processing algorithms used in the UX8800 differ from the normal textbook algorithms used in digital processors EAWdeveloped new algorithms specifically tailored for digital audio process...

Страница 37: ...Page 27...

Страница 38: ...Page 28...

Страница 39: ...Page 29...

Страница 40: ...One Main Street Whitinsville MA USA 01588 508 342 6158 FAX 508 234 8251 Part No 0018676 00 A00 June 2007 Loud Technologies Inc 2007...

Отзывы: