background image

CAM160 / CAM80 – 

9

GND and 100V are used to connect 100V speakers 

 

Use Class II wiring:

8. AC Power

The CAM160 and CAM80 are fitted with a detachable IEC 

socket for AC input.

Each unit is fitted with a universal power supply, allowing 

it to operate from any AC mains supply from 100 to 240 

VAC, 50-60 Hz.

A 6-foot U-Ground to IEC power cable is supplied.

An integrated, removable, AC input fuse is fitted just below 

the IEC socket. To remove or inspect the fuse, first unplug 

the power cord from the AC socket. Then use a small 

screwdriver to gently pry open the rectangular fuse holder 

and inspect or replace the fuse. Replacement fuses must 

be of the same rating as the original fuse.

Low voltage fuses are located internally.

9. DC Power

These terminals allow the amplifier to be powered using 24 

VDC emergency power supplies.

The unit will automatically switch to external DC battery 

power if your local AC power fails. You will need to 

connect an external 24 Volt battery to the DC battery 

terminals.

Make absolutely sure the positive post of your battery 

connects to the positive terminal, and the negative 

post connects to the negative terminal. To minimize the 

voltage drop across the wires and prevent overheating, use 

at least 14 AWG insulated wire.

The unit seamlessly switches to the backup supply if 

there's a power loss, allowing safety instructions and 

emergency communications to continue. When both AC 

power and 24 VDC power are connected, the AC power is 

used and no current is drawn from the DC supply.

Note:

 The unit will not charge the battery, so you should 

have a dedicated charging system. Note also, that when 

running on DC power, the output is lower than when 

running on AC power.

4 VDC

0

0

0

100V

100V

100V

Содержание CAM160

Страница 1: ...CAM160 CAM80 Integrated Mixer Amplifiers INSTRUCTION MANUAL...

Страница 2: ...VRIR CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL ATTENTION POUR EVITER LES RISQUES DE CHOC ELECTRIQ...

Страница 3: ...vided for connecting an external 24 VDC backup battery with automatic switching if the AC mains fails The front panel provides level controls for each mic line input aux and master volume as well as b...

Страница 4: ...tented center position there is no change in level The maximum boost and cut is 12 dB 4 EQ HIGH Turn this clockwise to boost the level of the high frequency range above 10 kHz Turn it counter clockwis...

Страница 5: ...DIP switch details 1 Mic line line level is default Select UP if using a microphone or DOWN if it is a line level input such as from a CD or DVD player Note You must set DIP 2 to the same setting as D...

Страница 6: ...Closing the switch actuates the Chime Inputs 3 4 5 6 Inputs 3 4 5 and 6 have identical connections and controls Input 3 is shown here INPUT CONNECTORS Inputs 3 6 each have two different styles of inp...

Страница 7: ...t level is controlled by a potentiometer just above the RCA jacks 22 Chime Level Control This potentiometer controls the chime level when it is actuated via contact closure at the chime barrier strip...

Страница 8: ...V 70 V or 100 V output terminal to the side of the speaker system and connect the upper GND output terminal to the side of the speaker system The voltage of your speakers must equal the voltage of th...

Страница 9: ...plifier to be powered using 24 VDC emergency power supplies The unit will automatically switch to external DC battery power if your local AC power fails You will need to connect an external 24 Volt ba...

Страница 10: ...nnector which can accept XLR and 1 4 TRS and TS plugs The AUX 1 and 2 inputs use unbalanced RCA connectors as does the MAIN IN and PREAMP OUT XLR Connectors Inputs 1 and 2 can accept 3 pin male XLR co...

Страница 11: ...TYPICAL HOOKUP DIAGRAM AM FM Tuner or CD Player AM FM Tuner or CD Player Graphic Equalizer in pre out main in loop 70V Loudspeakers AC Line Backup Battery 24 VDC Paging Priority Switch Telephone Cons...

Страница 12: ...idth at 1 dBr all modes 40 Hz 15 kHz 0 dB 3 dB Signal to Noise ratio 95 dBV Protection Heatsink Overtemp DC offset Short Circuit AC Line Input Power 100 VAC to 240VAC 50 60Hz 110 W CAM80 220 W CAM160...

Страница 13: ...h Pass Pad Enable 10 dB VOX Threshold VOX Threshold Priority 1 Priority 2 Priority 2 Priority 2 Priority 1 Priority 1 PRIORITY CHIME REMOTE VOLUME LOW EQ HIGH EQ AMPLIFIER MONITOR BOARD OUTPUTS 4 OHM...

Страница 14: ...ial through our website at www eaw com ContactUs 2 Pack the unit in its original packaging THIS IS VERY IMPORTANT LOUD Technologies is not responsible for any damage that occurs during shipping due to...

Страница 15: ...for parts or labor if the warranty applies Final determination of warranty coverage lies solely with each authorized EAW Commercial distributor What Is Not Covered This warranty does not extend to da...

Страница 16: ...logies Inc Company EAW Commercial One Main Street Whitinsville MA 01588 USA TEL toll free within US Canada 800 992 5013 TEL outside US 508 234 6158 FAX 508 234 8251 www eaw com 2007 2008 LOUD Technolo...

Отзывы: