background image

Manual

07/19 MN048025EN

XV360 Single Touch Display

Manual

Содержание XV360

Страница 1: ...Manual 07 19 MN048025EN XV360 Single Touch Display Manual ...

Страница 2: ...blication date 07 2019 1st Edition Version 0 0 Copyright 2015 by Eaton Industries GmbH 53105 Bonn Author Antje Panten Nonnen Electrical Sector Business Unit Industrial Automation Editor ICPD MOC Eaton Industries GmbH Hein Moeller Straße 7 11 D 53115 Bonn All rights including those of translation reserved No part of this manual may be reproduced stored in a retrieval system or transmitted in any fo...

Страница 3: ...uld be implemented for the I O interface so that a line or wire breakage on the signal side does not result in undefined states in the automation devices l Deviations of the mains voltage from the nominal value must not exceed the tolerance limits given in the specifications otherwise this may result in mal function and hazardous states l Emergency Stop devices complying with IEC EN 60204 1 must b...

Страница 4: ......

Страница 5: ...ption 13 1 1 Basic equipment common features of the model series 13 1 2 Device variants options 14 1 3 Intended use 14 1 4 Variants and types 15 1 5 Operating and indication elements 16 1 5 1 Overview 16 1 6 Interfaces to peripheral devices 17 1 7 What the different parts of the part number mean 18 1 8 Accessory devices 19 1 9 Nameplate 20 1 10 Support 20 2 Safety regulations 21 2 1 Basics 21 2 2 ...

Страница 6: ... 9 1 Power supply electrical connection 40 3 Commissioning 43 3 1 Initial commissioning 43 3 2 Running the XV 363 44 4 External connections 45 4 1 Layout of interfaces 46 4 2 SD card 47 4 3 USB interfaces 48 4 3 1 USB host 48 4 3 2 USB device 48 4 4 Ethernet 1 Ethernet 2 49 4 5 Serial interfaces for communication with PLCs or devices 50 4 5 1 COM1 RS 232 50 4 5 1 1 Wiring topic 51 4 5 2 COM2 RS 48...

Страница 7: ...transport 65 6 3 2 Disposal 66 Appendix 67 A 1 Technical data 68 A 1 1 Data sheets 68 A 1 2 Dimension and weight specifications 69 A 1 2 1 XV 363 57 69 A 1 2 2 XV 363 10 70 A 1 2 3 XV 363 12 71 A 1 2 4 Hole diameter built in 72 A 1 3 General data 73 A 1 4 Port and interface specifications 75 A 1 5 Information on the power supply 76 A 1 6 Approvals and declarations 77 A 2 Further reading 78 Alphabe...

Страница 8: ... engineering knowledge and skills It does not however go over the corresponding operating system or application soft ware Make sure to always use the latest documentation for your device Manual XV360 Single Touch Display MN048025EN The latest version of this documentation as well as additional references is available for download on the Internet Section Further reading page 78 http www eaton eu do...

Страница 9: ...AUTION Installation requires qualified electrician Follow the safety instructions for the XV 363 The section on safety instructions must be read and understood by everyone who will be working with the XV 363 before the actual work is performed Human machine interface WARNING Incomplete operator manual copies Working with individual pages taken out from the operator manual may lead to bodily injury...

Страница 10: ...h Display into automation processes Hazards posed by the XV 363 cannot be eliminated if the safety instructions are not observed especially if the XV360 Single Touch Display is commissioned and main tained by unqualified personnel and or the XV 363 is used improperly Eaton assumes no liability for any damages resulting from cases such as these 0 1 4 Device designations and abbreviations The follow...

Страница 11: ...e variable values that you must replace with your own values 0 1 5 1 Warning labels Risk of personal injury warning DANGER Warns of hazardous situations that result in serious injury or death WARNING Warns of the possibility of hazardous situations that could result in ser ious injury or even death DANGER Dangerous Electrical Voltage CAUTION Warns of the possibility of hazardous situations that ca...

Страница 12: ...ing useful additional information 0 1 5 2 Documents with additional information Manuals for example These will be listed with the corresponding title and Eaton num ber after the icon Publication title For identifying the Eaton publication code External Internet addresses They will be shown after the icon Destination address 12 XV360 Single Touch Display 07 19 MN048025EN www eaton eu ...

Страница 13: ...B Retain 3 Industrial Infra red touch display with Laminated safety glass non reflective in aluminum bezel 4 SD SDHC memory card slot 5 Operating System Windows Embedded Compact 7 pro 6 Every Human machine interface comes with a comprehensive basic con figuration with integrated interfaces l Two Ethernet ports 10 100 Mbit s for use as a communication or field bus interface l One USB 2 0 host port ...

Страница 14: ...Display are primarily intended for use in machine and system buil ding applications They are intended exclusively for monitoring operating and controlling machines and systems Any other use must be discussed and agreed upon with the manufacturer in advance The XV 363 are approved for use in closed spaces Bid The Human machine interface must be used only in locations for which the XV 363 is approve...

Страница 15: ... 4 inch display 24VDC IR 640 x 480 pixels 2xEthernet 1xRS232 1xRS485 1xCAN PLC function can be added 197666 XV 363 12 C00 A00 1B User interface 12 1 inch display 24VDC IR 800 x 600 pixels 2xEthernet 1xRS232 1xRS485 1xCAN PLC function can be added 197667 XV 363 57 C02 A00 1B User interface 5 7 inch display 24VDC IR 640 x 480 pixels 2xEthernet 1xRS232 1xRS485 1xCAN 1xDP PLC function can be added 197...

Страница 16: ...isplay Infrared touch sensor Display of HMI device Detects when the controls shown on the display are being actuated SD card slot Slot for SD card CTRL button The specific function depends on the software being used Infra red single touch The unit is operated by disrupting the grid like array of infrared light beams with a finger or a suitable object min diameter of 7 mm The infrared touchscreen g...

Страница 17: ...lvanically isolated plug type A Full power 500 mA USB device USB 2 0 not galvanically isolated plug type B Ethernet 1 RJ 45 socket 8 pole 2 LEDs CAT5e 6 LAN1 10 100 Mbps Ethernet 2 RJ 45 socket 8 pole 2 LEDs CAT5e 6 LAN1 10 100 Mbps COM1 RS 232 not galvanically isolated SUB D plug 9 pole UNC nuts for interlocking COM2 RS 485 not galvanically isolated SUB D plug 9 pole UNC nuts for interlocking CAN...

Страница 18: ...erfaces Version Visualization software Tab 1 Part number 363 363 Front mounting infrared Tab 2 Version 57 5 7 screen diagonal 10 10 4 screen diagonal 12 12 1 screen diagonal Tab 3 Display size C00 Base 2xEthernet 1xRS232 1xRS485 1xCAN 1x USB host 1xUSB device 1xSD card slot C02 Base 1xProfibus Tab 4 Interfaces A00 Standard version Tab 5 Version 1B WEC7P runtime license for GALILEO visualization so...

Страница 19: ...eaton eu ecat Example article no Catalog Number 139807 MEMORY SD A1 S SD memory card with min 256 MByte 181638 MEMORY SD A2 S SD memory card with min 1 GB 181585 LIC PLC A License product certificate for PLC upgrading 139828 ACCESSORIES TP 57 IR 1 for XV 363 57 Included as standard of the device 139843 ACCESSORIES TP 15 IR 1 for XV 363 10 and XV 363 12 Included as standard with the device XV360 Si...

Страница 20: ...cture l Required power supply l Serial No l Type approval and certification marks and information l Layout of ports interfaces and controls Fig 2 Example for a nameplate 1 10 Support To get fast and effective support make sure to always provide Customer Service with the following information from the nameplate l Part No l Serial No 20 XV360 Single Touch Display 07 19 MN048025EN www eaton eu ...

Страница 21: ...ever a hazard is indicated The hazard symbol and signal word used and the corresponding text will provide information regarding the specific hazard and how to avoid or prevent it 2 2 Mandatory requirements personnel requirements 2 2 1 Occupational safety All generally accepted occupational health and safety rules and standards internal and national must be complied with as must be all applicable l...

Страница 22: ...nstallation maintenance and disposal Make sure that the XV 363 is connected installed serviced and disposed of pro fessionally and in line with all relevant standards and safety rules CAUTION Installation requires qualified electrician Important Dispose of recyclables as required by your local recycling regulations Human machine interface XV 363 no longer being used must be professionally dis pose...

Страница 23: ...k Use the device in the following environments only l Non hazardous non explosive areas l Potentially explosive atmosphere Zone 22 according to ATEX Directive The ground resistance of accessible metal parts must be less than 109 ohms Make sure that the device is not exposed to dangerous impacts and other types of dangerous mechanical shock De energize the device before disconnecting plug connectio...

Страница 24: ... electrostatic sensitive components for more information ESD guidelines CAUTION INTERFERENCES The values specified in the technical data as well as the device s elec tromagnetic compatibility EMC cannot be guaranteed if the following are used unsuitable cables improperly assembled and terminated cables and or wiring that does not conform to the applicable standards Only use cables assembled and te...

Страница 25: ...LATED INTERFACES The XV 363 may be damaged by potential differences The GND terminals of all bus modules must be connected Do not connect the connector to the XV 363 or disconnect it without first de energizing the system CAUTION DATA LOSS If the SD card is being written to and a voltage drop occurs or the card is removed data may be lost or the SD card may be ruined Insert the SD card only when t...

Страница 26: ...ys will disrupt the infrared touch sensor Protect the Infra red touch display unit from direct sunlight and other sources of UV radiation CAUTION POINTY SHARP OBJECTS AND CORROSIVE LIQUIDS When cleaning the Infra red touch display l Do not use any pointy or sharp objects e g knives l Do not use aggressive or abrasive cleaning products or solvents Make sure that no liquids get into the device short...

Страница 27: ...nctional extra low voltage with protective separation The power transformer must conform to the relevant standards CAUTION FORCES ON THE ETHERNET INTERFACE Communications may be affected and the connection s mechanical components may be damaged if the Ethernet interface is subjected to strong vibrations or the RJ45 plug in connection is subjected to pulling l Protect the RJ45 plug in connection fr...

Страница 28: ...elines for electrostatic sensitive components for more information ESD guidelines 2 4 Prerequisites for the location of use The XV 363 must be used as intended and exclusively in locations for which the Human machine interface has been approved certified A 24 VDC supply voltage must be ensured as per the specifications XV 363 units are intended to be flush mounted in control cabinets control panel...

Страница 29: ...ure that the controls and connectors on the device s service side will remain accessible after the device has been installed The SD card slot is located on the side of the XV 363 Do not install the device with the SD card slot facing downwards as the SD card may fall out Make sure to take the space required to remove the SD card into account 35 mm 1 37 Fig 3 Space required to remove the SD card l ...

Страница 30: ...ents emitting heat such as transformers under heavy loads is 15 cm The environmental ambient conditions for operation must not exceed the specified values Ambient climatic conditions Air pressure in operation 795 1080 hPa Max 2000 m above sea level Temperature Operation 0 50 C 32 122 F Storage Transport 20 60 C 4 140 F Humidity Relative humidity 10 95 Condensation non condensing 30 XV360 Single To...

Страница 31: ... will be enough volume for air changes inside the control panel etc The specified clearance around the XV 363 is a b c 30 mm 1 18 l If you will be installing the XV 363 in complex systems together with other assem blies you must ensure that there will be enough air circulation in order to prevent overheating Ambient temperature with natural convection ϑ 0 C 32 F T 50 C 122 F The panel builder is r...

Страница 32: ...ervice 49 0 180 5 223822 de en The package for the XV360 Single Touch Display comes with Unit Description 1 x XV 363 57 XV 363 10 or XV 363 12 1 x Plug connector MSTB 2 5 3 ST 5 08 1 x Installation instructions IL048014ZU 8 x Holding bracket with set screw Internal hexagon M 4 x 25 DIN 914 galvanized 1x Gasket cord Cord gasket XV 363 57 NR material foamed light gray diameter of 3 1 mm 0 12 800 mm ...

Страница 33: ...ts in the control panel If necessary reinforcing elements must be installed added An IP65 degree of protection will only be ensured if there is sufficient stiffness and the device is properly mounted l Minimum sheet thickness of control panel panel where the device will be flush mounted 2 mm 0 08 d 5 mm 0 2 List of tools l 2 0 m Allen key l PZ2 Pozidriv screwdriver l Torque wrench with Newton mete...

Страница 34: ...d 5 mm 0 2 at the installation cutout and a flatness 0 5 mm 0 02 with a surface roughness Rz 120 IP 65 DIN ISO 2768 2 K l The size of the installation cutout depends on the device type XV 363 57 e 198 mm 7 79 1 mm 0 04 f 142 mm 5 59 1 mm 0 04 XV 363 10 e 329 mm 12 95 1 mm 0 04 f 238 mm 9 37 1 mm 0 04 XV 363 12 e 344 mm 13 54 0 5 mm 0 02 f 262 mm 10 31 1 mm 0 04 d e f Fig 6 flush mounted 4 Check th...

Страница 35: ...such a way that there will be no gap between the two ends 7 Place the end of the gasket cord inside the groove CAUTION POOR SEALING If the gasket cord is twisted when placed inside the groove or does not provide adequate sealing all around the degree of protection will not be achieved The join of the sealing strip must be positioned on the bottom of the device 8 Check that the gasket is resting pr...

Страница 36: ...o the enclosure sideways and screwed against the control panel door etc The positions of the retaining brackets depend on l The device type l The requirements for installation and for the required degree of protection Locations for the 4 holding brackets for an IP20 degree of protection l On the top and bottom sides of the device One holding bracket each at the left and right outer fixing position...

Страница 37: ...363 12 XV 363 10 l On the top and bottom sides of the device One holding bracket each at the left and right fixing positions l On the left and right sides of the device One holding bracket each at the left and right fixing positions IP65 8x Fig 12 Location of holding brackets for IP65 on XV 363 10 XV360 Single Touch Display 07 19 MN048025EN www eaton eu 37 ...

Страница 38: ...77 lb in Fig 14 Installing the holding brackets 4 Tighten the set screw until it comes into contact with the installation surface 5 Follow steps 3 and 4 to insert the next holding bracket at a 90 angle to the last one you inserted 6 Repeat steps 3 and 4 until all necessary holding brackets are installed 7 Check that the device is in its correct centered position and that the gasket is in contact a...

Страница 39: ...tion is present there will be a short circuit hazard Do not switch on the device when it has condensation in or on it If the Infra red touch display has condensation in or on it or if it has been exposed to environmental fluctuations let the XV 363 settle into the existing ambient temperature before switching it on Do not expose the device to direct thermal radiation from heating appliances Before...

Страница 40: ...nsumption at 24 V DC 17 W for basic device 2 5 W for USB module XV 363 10 max 20 5W Current consumption at 24 V DC 18 W for basic device 2 5 W for USB module XV 363 12 max 20 5W Current consumption at 24 V DC 18 W for basic device 2 5 W for USB module Fuse Yes fuse not accessible Potential isolation no Electrical current 5 7 display 10 4 display 12 1 display Ie 1 A 1 A 1 A ITH 2 5 A s 3 0 A s 3 0 ...

Страница 41: ...Fig 16 Power supplied through Plug connector MSTB 2 5 3 ST 5 08 Use the Plug connector MSTB 2 5 3 ST 5 08 to terminate the connection cable for the power supply in advance Plug the pre assembled plug into the socket on the enclosure Pay attention to the polarity 24V and 0V Connect the power supply cable to a 24 VDC supply voltage that meets the requi rements for safety extra low voltages SELV set ...

Страница 42: ...2 Installation 2 9 Preparing the device for operation 42 XV360 Single Touch Display 07 19 MN048025EN www eaton eu ...

Страница 43: ...itching it on Do not expose the device to direct thermal radiation from heating appliances Apply a XV 363 to the 24 VDC supply voltage unit The XV 363 unit will boot up The XV 363 does not come with any runtime software for visu alization or for use as an HMI installed In order to upgrade a unit to an HMI that can be used for con trol and operating purposes use license product certificate LIC PLC ...

Страница 44: ...r words it does not have to be separately switched on and off Reducing the level of brightness will increase the display backlight s lifespan Follow the instructions in the following section if your XV 363 until will not boot up and or if an error message appears Section Faults page 61 See also System description Windows CE 7 MN050004EN 44 XV360 Single Touch Display 07 19 MN048025EN www eaton eu ...

Страница 45: ...o the cable CAUTION INTERFERENCES The values specified in the technical data as well as the device s elec tromagnetic compatibility EMC cannot be guaranteed if the following are used unsuitable cables improperly assembled and terminated cables and or wiring that does not conform to the applicable standards Only use cables assembled and terminated by professionals The cables being used must be asse...

Страница 46: ...thernet 1 RJ 45 socket 8 pole 2 LEDs CAT5e 6 LAN1 10 100 Mbps Ethernet 2 RJ 45 socket 8 pole 2 LEDs CAT5e 6 LAN1 10 100 Mbps COM1 RS 232 not galvanically isolated SUB D plug 9 pole UNC nuts for interlocking COM2 RS 485 not galvanically isolated SUB D plug 9 pole UNC nuts for interlocking CAN CAN1 not galvanically isolated SUB D plug 9 pole UNC nuts for interlocking Optional interfaces XV 363 C02 P...

Страница 47: ...in progress data loss is highly likely to occur Remove the SD card only when the XV 363 is de energized Before switching off the device make sure that there are no pro grams writing to the SD card Inserting the SD card SD cards cannot be inserted the wrong way around Do not use force when inserting the card Push the SD card into the SD card slot until you feel it lock into place Removing the SD ca...

Страница 48: ...ind that their EMC interference immunity parameters may render them unsuitable for use in industrial environments The USB ports USB host and USB device on the XV 363 are intended exclusively for maintenance work Only use standard USB cables with a shield Max cable length 5 m 4 3 1 USB host Fig 19 USB 2 0 not galvanically isolated plug type A Full power 500 mA 4 3 2 USB device The USB device interf...

Страница 49: ...bles only For connecting The XV 363 to a device l Use a crossover cable The XV 363 to a hub switch l Use a patch cable 1 1 Max cable length 100 m CAUTION FORCES ON THE ETHERNET INTERFACE Communications may be affected and the connection s mechanical components may be damaged if the Ethernet interface is subjected to strong vibrations or the RJ45 plug in connection is subjected to pulling l Protect...

Страница 50: ...onnected Do not connect the connector to the XV 363 or disconnect it without first de energizing the system SUB D plug PIN signal Description 9 pole 1 2 3 4 5 6 9 8 7 1 DCD Data Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set Ready 7 RTS Request to Send 8 CTS Clear To Send 9 RI Ring Indicator Plug housings GND Functional earth Tab ...

Страница 51: ... depends on the cable length Cable length Max baud rate 2 5 m 115200 Bit s 5 m 57600 Bit s 10 m 38400 Bit s 15 m 19200 Bit s 30 m 9600 Bit s Tab 11 RS 232 cable length based on baud rate When preparing connections ensure that the cable shield has a low impedance connection with the connector housing XV360 Single Touch Display 07 19 MN048025EN www eaton eu 51 ...

Страница 52: ...cable 8 n c not used 9 n c not used Plug housings GND Functional earth Tab 12 Pin assignment COM2 RS 485 not galvanically isolated SUB D plug 9 pole UNC nuts for interlocking n c PIN 1 2 4 8 and 9 must not be connected Pin 6 5 V must not be used as a power supply for external devices 4 5 2 1 Wiring topic l Screened twisted pair cables must be used l The maximal baud rate depends on the cable lengt...

Страница 53: ...facturer A bus segment must be provided with cable termination 120 Ohm at both ends These terminals must be connected in the plug directly between pin 3 and 7 The bus segment must be terminated at both ends There must not be more than two terminations per bus segment Running the bus segment without the right termination may result in transmission errors 1 2 3 6 7 5 4 8 9 120 1 2 3 6 7 5 4 8 9 120 ...

Страница 54: ... PIN signal Description 9 pole 1 2 3 4 5 6 9 8 7 1 n c not used 2 CAN L Bus line dominant low 3 GND Ground 4 n c not used 5 n c not used 6 GND Optional Ground 7 CAN H Bus line dominant high 8 n c not used 9 n c not used Tab 14 PIN assignment for CAN interface as specified in CiA CAN1 not galvanically isolated SUB D plug 9 pole UNC nuts for interlocking l nc PIN 1 4 5 8 and 9 must not be connected ...

Страница 55: ...twisted pair cables must be used Rated cable impedance 120 Ohm Permissible impedance 108 132 Ohm Capacitance per unit length 60 pF m Core cross section With a max cable length of 100 m 0 25 mm2 250 m 0 34 mm2 500 m 0 75 mm2 Tab 15 Specifications for CAN wiring XV360 Single Touch Display 07 19 MN048025EN www eaton eu 55 ...

Страница 56: ...ault settings 100 m 500 kBit s default settings 250 m 250 kBit s default settings 500 m 125 kBit s default settings 500 m 100 kBit s can be set through soft ware 1000 m 50 kBit s default settings 2500 m 20 kBit s default settings 5000 m 10 kBit s default settings When preparing connections ensure that the cable shield has a low impedance connection with the connector housing 56 XV360 Single Touch ...

Страница 57: ... documentation for repeaters provided by man ufacturer Make sure to follow the recommendations provided by CiA CAN in Automation at http www can cia org A bus segment must be provided with cable termination 120 Ohm at both ends These terminals must be connected in the plug directly between pin 2 and 7 The bus segment must be terminated at both ends There must not be more than two terminations per ...

Страница 58: ...t PIN signal Description 9 pole 1 2 3 4 5 6 9 8 7 1 n c not used 2 n c not used 3 B EIA RS 485 cable B 4 RTSAS Output for controlling a repeater 5 M5EXT GND Output 0 V for external termination Ground 6 P5EXT Output 5 V for external termination 7 n c not used 8 A EIA RS 485 cable A 9 n c not used Tab 16 Pin assignment for Profibus DP not galvanically isolated SUB D socket 9 pole UNC nuts for interl...

Страница 59: ...sistance 100 Ohm km Core cross section 0 34 mm2 22 AWG The maximal baud rate depends on the cable length Possible baud rates With a max cable length of 100 m 12000 kBit s 12MBit s 200 m 1500 kBit s default settings 400 m 500 kBit s default settings 1000 m 187 5 kBit s default settings 1200 m 93 75 kBit s Tab 17 Specifications for Profibus wiring When preparing connections ensure that the cable shi...

Страница 60: ...ovided with cable termination at both ends This termination is passive but is fed from the node It ensures a defined quiescent signal on the bus if no bus station is sending These bus terminations are preferably implemented extern ally in the connector housing as per the PROFIBUS standard and can be implemented using the aforementioned bus connector plugs 1 2 3 6 7 5 4 8 9 390 390 1 2 3 6 7 5 4 8 ...

Страница 61: ... Windows Embedded Compact 7 pro system descrip tion or to the corresponding function in the visualization soft ware The Infra red single touch is not responding or is responding incorrectly when used The infrared touchscreen display s infrared frame is soiled Clean the infrared frame The set screws are too tight Loosen the set screws see Mounting Page 38 The touch is disabled Switch on XV 363 Enab...

Страница 62: ...5 Faults 62 XV360 Single Touch Display 07 19 MN048025EN www eaton eu ...

Страница 63: ... the Infra red touch display l Do not use any pointy or sharp objects e g knives l Do not use aggressive or abrasive cleaning products or solvents Make sure that no liquids get into the device short circuit hazard and that the XV 363 is not damaged in any way Clean the infrared frame and the display with a clean soft damp cloth 6 1 2 Battery The internal battery used to back up the real time clock...

Страница 64: ...pport CAUTION DESTRUCTION The XV 363 should only be opened by the manufacturer or by an author ized center Operate the Infra red touch display until only with the enclosure fully closed and sealed Use the original packaging to ship the device 64 XV360 Single Touch Display 07 19 MN048025EN www eaton eu ...

Страница 65: ...XV 363 settle into the existing ambient temperature before switching it on Do not expose the device to direct thermal radiation from heating appliances The ambient conditions must be met when transporting and storing the XV 363 The ambient air temperature for storage and transportation must not exceed the max imum specified limit 20 60 C 4 140 F Before commissioning If storing transporting the dev...

Страница 66: ...splay unit professionally Assembly part Material Display Laminated safety glass non reflective in aluminum bezel Back of the housing Display CPU interfaces Metal Insulated material black Battery Lithium BR 2330 GNU 3V 255 mAh Weight g 3 7 SVHC Substance 1 2 dimethoxyethane ethylene glycol dimethyl ether EGDME Substance weight 2 4 Tab 18 Materials used XV360 Single Touch Display Materials used in t...

Страница 67: ... 2 Dimension and weight specifications 69 A 1 3 General data 73 A 1 4 Port and interface specifications 75 A 1 5 Information on the power supply 76 A 1 6 Approvals and declarations 77 A 2 Further reading 78 XV360 Single Touch Display 07 19 MN048025EN www eaton eu 67 ...

Страница 68: ...nction can be added 197666 XV 363 12 C00 A00 1B User interface 12 1 inch display 24VDC IR 800 x 600 pixels 2xEthernet 1xRS232 1xRS485 1xCAN PLC function can be added 197667 XV 363 57 C02 A00 1B User interface 5 7 inch display 24VDC IR 640 x 480 pixels 2xEthernet 1xRS232 1xRS485 1xCAN 1xDP PLC function can be added 197668 XV 363 10 C02 A00 1B User interface 10 4 inch display 24VDC IR 640 x 480 pixe...

Страница 69: ...5 mm 8 46 62 mm 2 44 156 2 mm 6 15 159 mm 6 26 121 2 mm 4 78 139 2 mm 5 47 8 mm 0 31 28 mm 1 10 53 mm 2 08 5 mm 0 2 Fig 25 Dimensions for 5 7 front mounting devices in mm inches Width x Height x Depth without plug 212 2 mm x 156 2 mm x 67 0 mm 8 36 x 6 15 x 2 46 Weight 1 8 kg 3 96 lbs XV360 Single Touch Display 07 19 MN048025EN www eaton eu 69 ...

Страница 70: ...16 327 2 mm 12 88 345 mm 13 58 347 mm 13 66 57 5 mm 2 26 68 5 mm 2 70 106 mm 4 17 5 mm 0 2 Fig 26 Dimensions for 10 4 front mounting devices in mm inches Width x Height x Depth without plug 345 2 mm x 260 2 mm x 67 0 mm 13 58 x 10 23 x 2 46 Weight 3 4 kg 7 49 lbs 70 XV360 Single Touch Display 07 19 MN048025EN www eaton eu ...

Страница 71: ...1 2 mm 14 22 362 mm 14 25 279 2 mm 10 99 280 mm 11 02 70 mm 2 76 81 mm 3 19 118 mm 4 65 5 mm 0 2 Fig 27 Dimensions for 12 1 front mounting devices in mm inches Width x Height x Depth without plug 361 2 mm x 279 2 mm x 67 9 mm 14 22 x 10 99 x 2 50 Weight 3 8 kg 8 37 lbs XV360 Single Touch Display 07 19 MN048025EN www eaton eu 71 ...

Страница 72: ... 02 with a surface roughness Rz 120 IP 65 DIN ISO 2768 2 K l The size of the installation cutout depends on the device type XV 363 57 e 198 mm 7 79 1 mm 0 04 f 142 mm 5 59 1 mm 0 04 XV 363 10 e 329 mm 12 95 1 mm 0 04 f 238 mm 9 37 1 mm 0 04 XV 363 12 e 344 mm 13 54 0 5 mm 0 02 f 262 mm 10 31 1 mm 0 04 72 XV360 Single Touch Display 07 19 MN048025EN www eaton eu ...

Страница 73: ...echnology Infra red single touch Operating System Windows Embedded Compact 7 pro Processor ARM Cortex A9 800 MHz Internal memory DRAM 512 MB RAM flash memory 1 GB SLC NVRAM 128 kB Retain SD card slots One SDSC or SDHC conforming to the SDA 2 0 specification use genuine accessories only Cooling Fanless CPU and system cooling natural convection based passive cooling Back up of real time clock Batter...

Страница 74: ... 363 57 115 mm x 86 mm XV 363 10 211 mm x 158 mm XV 363 12 246 mm x 185 mm Contrast ratio Normally normally 500 1 Brightness Normally 400 cd m2 Backlight LED dimmable via software Lifespan of backlight Normally 50000 h at 25 C Ambient climatic conditions Air pressure in operation 795 1080 hPa Max 2000 m above sea level Temperature Operation 0 50 C 32 122 F Storage Transport 20 60 C 4 140 F Humidit...

Страница 75: ...0 100 Mbps USB Host USB 2 0 not galvanically isolated 1 x USB device USB 2 0 not galvanically isolated RS 232 not galvanically isolated SUB D plug 9 pole UNC RS 485 not galvanically isolated SUB D plug 9 pole UNC CAN not galvanically isolated SUB D plug 9 pole UNC Profibus DP not galvanically isolated D Sub bus 9 pole UNC Tab 19 Interfaces communication XV360 Single Touch Display 07 19 MN048025EN ...

Страница 76: ...of 100 ms Voltage dips Ability to accommodate brief voltage dips 10 ms from rated operating voltage 24 V DC 5 ms from undervoltage 19 2 V DC Power consumption XV 363 57 max 19 5W Current consumption at 24 V DC 17 W for basic device 2 5 W for USB module XV 363 10 max 20 5W Current consumption at 24 V DC 18 W for basic device 2 5 W for USB module XV 363 12 max 20 5W Current consumption at 24 V DC 18...

Страница 77: ... ATEX directive 94 9 EG 2014 34 EG IEC EN 60079 0 Explosive atmospheres Equipment General require ments IEC EN 60079 31 Explosive atmospheres Equipment dust ignition protection by enclosure t Security IEC EN 60950 Safety of Information Technology Equipment DIN EN 60529 Degrees of protection provided by enclosures Product standards DIN EN 60898 1 2006 03 Electrical accessories Circuit breakers for ...

Страница 78: ...configured as appropriate for the PLC being used The following documents together with other documentation explain what needs to be taken into account and configured Networks in Brief MN05010009Z XSOFT CODESYS 2 XV300 PLC programming user manual MN048015ZU XSOFT CODESYS 3 PLC programming user manual MN048008ZU Download Center Eaton Online Catalog Enter XV 363 into the search box and the catalog wi...

Страница 79: ...leaning 63 COM1 17 46 COM2 17 46 Commissioning 43 Company information 2 Connections External 45 Cooling 73 Copy protected 2 Copyright 2 CTRL button 16 Current 40 76 D Damage 32 Declarations 77 Degree of protection 73 Description 13 Device variants 14 Dimensions 69 Directives 77 Display 16 74 Disposal Recycling 66 Download Center 78 E Eaton Safety instructions I ecat 78 Equipment supplied 32 Ethern...

Страница 80: ...sensor 16 J J1939 54 L Label 20 Lifespan 74 Backlight 44 List of revisions 8 Location of use 28 M Maintenance 63 Manuals 78 Materials used 66 Missing parts 32 Mounting 33 Mounting distance 31 Mounting position SD card 29 N Nameplate 17 20 O Online Catalog 78 Operating elements 16 Operation Proper 22 Original Operating Instructions 2 P Package contents 32 Part number 18 Ports 45 Power consumption 4...

Страница 81: ...46 Service 20 Service page 16 Standards 77 Std pack 32 Storage 65 Support 20 System 73 T Technical data 68 Transit damage 32 Transport 65 Troubleshooting 61 U USB device 17 46 48 USB host 17 46 48 USB peripheral devices 48 V Versions 18 Voltage range 40 76 W Weight 69 XV360 Single Touch Display 07 19 MN048025EN www eaton eu 81 ...

Страница 82: ...company with 2017 sales of 20 4 billion dollars We provide energy efficient solu tions that help our customers effectively manage electrical hydraulic and mechanical power more efficiently safely and sustainably Eaton is dedicated to improving people s quality of life and the environment through the use of power management technologies and services Eaton has approximately 96 000 employees and sell...

Отзывы: