xChargeIn
Read off device information and meter reading
Manual for MID variants V1.01
15
© EATON
5
Read off device information and meter reading
No special access rights are required for reading off the information.
Information
The required energy for setting the charging station by the manufacturer
and for the commissioning process are part of the total energy. For this rea-
son, the meter reading will not have the value "0" after the installation has
been completed
The following checks must be carried out in order to make sure that the me-
ter reading is valid.
5.1
Necessary checks
The following points must be checked in order to accept the meter reading
as valid.
●
Integrity of the charging station and associated components such as
charging cable, charging connector or charging socket
●
Sufficient period of validity of the calibration according to the calibration
plate. The information is visible on the type plate after initial placing on
the market or on the front part when calibrated.
●
Correct product designation according to type plate (see
)
●
Correct function of the display and sufficient readability of the meter
reading
●
Undamaged seal on the connection panel cover or terminal cover
●
Undamaged meter seal on the front part with the number 3002 2073
5.2
Trigger information display
A display of the device information and the meter reading on the display can
be triggered during the following activities:
●
Start and end of a charging process
●
Start or restart of the charging station
For more information see "Operating Instructions".
In addition, the information display can also be triggered via the brightness
sensor.