background image

ii

Xenon beacon Xb11

   TM135   February 2023   www.eaton.com

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY

The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation’s 

(“Eaton”) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales 

office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in 

appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser.
THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING 

WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE 

SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE 

ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY 

ANY CONTRACT BETWEEN THE PARTIES. 
In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or 

other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to 

damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the 

use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the 

information, recommendations and descriptions contained herein. The information contained in this manual is subject to 

change without notice. 

Содержание XB11

Страница 1: ...Xenon beacon XB11 Technical manual...

Страница 2: ...PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHA...

Страница 3: ...n XB11 TM135 February 2023 www eaton com Contents 1 0 INTRODUCTION 1 2 0 INSTALLATION 1 General 1 Cable termination 1 3 0 OPERATION 2 4 0 MAINTENANCE 2 Removing replacing xenon tube 2 5 0 CERTIFICATIO...

Страница 4: ...iv Xenon beacon XB11 TM135 February 2023 www eaton com...

Страница 5: ...he following formula to determine length of fixing screw required Length of screw Thickness of mounting surface 10mm There are 2 off 8 5mm mounting holes in the optional backstrap These have been desi...

Страница 6: ...mbly ensure that the power to the unit is isolated Unscrew and remove the 6 off M5 4 0mm A F hexagon key Keep in a safe accessible location as they are noncaptive Twist the cover assembly gently clock...

Страница 7: ...tegory marking II 2 GD Where Signifies compliance with ATEX II Signifies suitability for use in surface industries 2 Signifies suitability for use in a zone 1 area G Signifies suitability for use in t...

Страница 8: ...35 February 2023 www eaton com Contents 1 0 INTRODUCTION 5 2 0 INSTALLATION 5 G n ralit s 5 Connexion des c bles 5 3 0 FONCTIONNEMENT 6 4 0 MAINTENANCE 6 Remplacement du tube au x non 6 5 0 CERTIFICAT...

Страница 9: ...fixation directe la formule suivante doit tre utilis e pour d terminer la longueur des vis requises Longueur de la vis paisseur de la surface de montage 10mm Le collier en option est pourvu de deux or...

Страница 10: ...nettoyage s av re n cessaire veillez nettoyer uniquement l ext rieur avec un chiffon l g rement humide afin d viter l accumulation d lectricit statique Le remplacement du tube au x non voir ci dessous...

Страница 11: ...temp poussi res Tx Plage de temp ambiante Temp ambiante T4 T105 C de 55 C 70 C T5 T90 C de 55 C 55 C T6 T75 C de 55 C 40 C Le certificat IECEx et l tiquette du produit portent mention du niveau de pr...

Страница 12: ...t galement des homologations CEM suivantes Perturbations conduites CC EN61000 6 3 2007 Immunit aux champs rayonn s CC et CA EN61000 6 2 2005 IEC61000 4 3 2002 Transitoires lectriques rapides salves CC...

Страница 13: ...EE und im National Electrical Code Sicherheitsstandard f r Elektroinstallationen in den USA M glicherweise gelten weitere lokale und oder nationale Bestimmungen Stellen Sie sicher dass alle Muttern Sc...

Страница 14: ...liche externe Einfl sse oder aggressive Substanzen hinweisen denen das Ger t ausgesetzt sein k nnte Stellen Sie sicher dass das Ger t vor direktem staubbelastetem Luftstrom gesch tzt ist der eine Ladu...

Страница 15: ...ng richtig an der Abdeckung sitzt Stellen Sie sicher dass nach dem Zusammensetzen der erforderliche Maximalspalt von 0 2mm zwischen Abdeckung und Sockel besteht 5 0 Zertifizierung genehmigungen IECEx...

Страница 16: ...nformierten Beh rde die das EC Pr fzertifikat ausstellt Die ATEX und IECEx Einheiten verf gen au erdem ber die folgenden EMC Genehmigungen Weitergeleitete Emissionen DC gem EN61000 6 3 2007 St rfeldim...

Страница 17: ...s de cabeamento do IEE Instituto Americano de Engenheiros Eletricistas e o National Electrical Code C digo El trico Nacional americano Podem ser aplic veis outros requisitos nacionais e ou locais Cert...

Страница 18: ...re a tampa e a base depois de montada O comprador cliente deve informar a Eaton sobre quais quer efeitos externos ou subst ncias agressivas aos quais o equipamento possa estar exposto Certifique se de...

Страница 19: ...F nos furos presentes na tampa e aperte os uniformemente Certifique se de que a guarni o O ring assente corretamente na tampa durante a remontagem Certifique se de que a folga requerida m xima de 0 2...

Страница 20: ...75 C de 55 C a 40 C O certificado ATEX e a etiqueta de produto cont m a marca o do grupo e da categoria ATEX II 2 GD Onde Significa a conformidade com as normas ATEX II Significa adequa o para uso em...

Страница 21: ...iu o certificado de exame CE de tipo As unidades ATEX e IECEx tamb m possuem as seguintes aprova es EMC Emiss es conduzidas DC para EN61000 6 3 2007 Imunidade a Campo Irradiado DC e AC a EN61000 6 2 2...

Страница 22: ...18 Xenon beacon XB11 TM135 February 2023 www eaton com Xenon beacon XB11 Eaton 3 0 M5 X 10 1 8 5 1 4 0 Ex MEDC MEDC MEDC...

Страница 23: ...5 C 55 C T6 T75 C 55 C 40 C IECEx IECEx Gb Db Gb 1 Db 21 ATEX EN60079 0 EN60079 1 EN60079 31 Ex d ATEX No BAS99ATEX2195 Ex d IIC T T Gb Ex tb IIIC T T Db IP66 IP67 Tx Tx T4 T105 C 55 C 70 C T5 T90 C 5...

Страница 24: ...contained in this document and to prices are reserved so are errors and omissions Only order confirmations and technical documentation by Eaton is binding Photos and pictures also do not warrant a sp...

Отзывы: