![Eaton VICKERS SystemStak Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/eaton/vickers-systemstak/vickers-systemstak_manual_4149130042.webp)
17
Eaton Vickers
Solenoid Operated Directional Valves
Product Catalog V-VLDI-MC011-E September 2008
Electrical Plugs
and Connectors
Cable diameter range:
Ø6–10 mm (0.24–0.40)
Wire section range:
Ø,5–1,5 mm2 (0.0008–
0.0023 in2)
Terminals:
Screw type
Type of protection:
IEC144 class IP65, when
plugs are fitted correctly to
the valves with interface
seals (supplied with plugs)
in place.
DIN 43650 Connector
Connector can be positioned
at 90° intervals on valve by
re-assembling contact holder
into appropriate position
inside connector housing.
Use U12 or U11 type connec-
tors with 12 and 24V DC coils
if rectification is required.
Connectors with and without
indicator lights are available
(order separately):
Recptacle
Voltage
Part Numbers
(AC or DC)
Gray –
Black –
"A" sol.
"B" sol.
U1 Coils
–
710776
710775
without lights
U6 Coils
12-24
977467
977466
with lights
100-125
977469
977468
200-240
977471
977470
U11 Rectified
12 DC
02-141358
coils with
24 DC
02-141359
lights
98-240 VDC
02-141360
200-240 VDC
02-141361
U12 Rectified
02-141357
coils without
lights
Surge Suppression Devices
(For DC Valves)
Standard diode
Diode in parallel with coil.
When switch (S
1
) is opened,
the energy stored in the coil
is trapped and dissipated by
the diode (D
1
).
• Works only with DC voltage
• Polarity dependent
• Increase drop out time
Transzorb
Diode and Zener diode in par-
allel with coil. When switch
(S
1
) is opened, the energy
stored in the coil is trapped
and dissipated by the diode
(D
1
) and Zener diode (Z
1
) and
the coil resistance.
• The Zener makes exact limi
-
tation of inductive spikes.
• Works only with DC voltage
• Polarity dependent
NOTE: These surge suppres
-
sion devices are “Polarity
Dependent.” Proper biasing
conditions must be met
when installing/connecting
a coil in a system.
Valve Shift and Dropout
Times with and without
Surge Suppression
Shift Dropout
CETOP 3
Do Diode
23
60
Diode Alone 23
131
Diode/Zener 23
78
CETOP 5
Do Diode
70
50
Diode Alone 70
158
Diode/Zener 70
100
Times represent cessation/
application of voltage to coil
versus velocity (start/stop)
of a cylinder using a single
solenoid, spring offset valve
(time in milliseconds).
Seal
51(2.01)
27
(1.06)
22,5
(0.88)
M3
thread
5,5
(0.22)
1,5
(0.06)
30,5 sq.
(1.20)
26,5
(1.04)
27,5
(1.08)
18 sq.
(0.71)
Coil
Coil
(No 2)
S
1
(No 1)
(No 2)
S
1
(No 1)
D
1
D
1
Z
1