5
2. Technical data
Pump performance:
15 L/min at 2800 rpm
E-motor:
0.18 KW, 2800 rpm
Alternating current:
230 V, 50 Hz
Compressive load capacity:
max. 4 bar
Filter fineness:
10 μm(c)
Weight:
approx. 14 kg
Operating medium:
see 1.5; 10 to 400 mm²/s
Other media on request
3. Commissioning
3.1. Initial and idle condition
The circulating filter unit is supplied in a ready-to-use condition. The initial and idle condition is
characterized as follows:
•
The filter unit is not connected to the power supply network.
•
The combined OFF - ON switch and motor-protective circuit breaker is switched off (switch
position O).
•
Suction and drain hoses are wound up. The open ends of the hose line are located in the
respective holding tubes.
•
The filter is equipped with a ready-to-use filter cartridge.
•
The filter is empty.
The initial and idle condition must be restored after operation and after repair or maintenance.
3.2. Operational readiness
The cleanliness of the open hose ends, especially those of the drain hose, must be checked each
time before commissioning. Contaminants must be removed with solvent before the hose ends
come into contact with the operating fluid to be filtered.
The suction and drain hose must be attached to the respective connection points and immersed in
the operating fluid.
The open end of the suction hose must be immersed in the operating fluid by at least 100 mm
during operation.
It must be ensured that the circulating fluid can enter and exit freely at the open ends of the hose
lines.
The circulating filter unit is switched on and off using the combined OFF - ON switch and motor-
protective circuit breaker.