Eaton SPD Series for Mounting External

to Electrical Distribution Equipment

Instruction Manual 

IM01005031E - Rev. 4

1.0 Introduction

1.1 Manual Organization

This Installation Manual describes the safe installation, testing 

and operation of the Eaton

®

 SPD Series Surge Protective Device 

(SPD). 
This manual is organized into seven sections, as follows:
 

1.0 Introduction

 

2.0 Installation

 

3.0 Operating Features

 

4.0 Troubleshooting 

 

5.0 Specifications

 

6.0 Ordering Guidelines

 

7.0 Warranty

1.2 Product Overview

The Eaton SPD Series protects critical electrical and electronic 

equipment from damage by power surges. This is done by 

shunting high energy lightning surges (and other transient dis-

turbances) away from the equipment being protected. It does 

this in nanoseconds by providing a low impedance surge path to 

ground while supporting power frequency voltage. 
The Eaton SPD Series is designed to mount on the wall (or other 

vertical surface) as close as possible to the electrical cabinet. 

The SPD Series is available in voltage ratings from 120-600V AC, 

surge current capacity ratings from 50kA to 400kA, and NEMA 

1, NEMA 4 or NEMA 4X enclosures..
The Eaton SPD Series is available in three feature pack-

ages (Basic, Standard, and Standard with Surge Counter), as 

described in Section 3, "Operating Features." Each model is avail-

able in Delta, Wye, and Split Phase wiring configurations.  
All Eaton SPD Series models have been tested and certified by 

Underwriter’s Laboratory (UL

®

), to comply with UL Standard 

1449, 3

rd

 Edition.  

Eaton’s One-Port low-voltage Surge Protective Device 

Delta Models 

SPD120480D3M, SPD160480D3M 

and 

SPD200480D3M

 meet the requirements of IEC 61643-11 / EN 

61643-11, Part 11: Test Class II, and are intended to be installed 

in applications with a degree of protection rated IP 20.

1.3 Safety Precautions

A licensed/qualified electrician must complete all instructions 

in this manual in accordance with the National Electric Code 

(NEC

®

), state, and local codes, or other applicable country 

codes. All applicable local electrical codes supersede these 

instructions. 

WARNING

IMPROPER INSTALLATION COULD CAUSE DEATH, INJURY AND 

EQUIPMENT DAMAGE. FOLLOW ALL WARNINGS AND CAUTIONS. 

COMPLETELY READ AND UNDERSTAND THE INFORMATION IN THIS 

INSTRUCTION MANUAL BEFORE ATTEMPTING TO INSTALL OR OPER-

ATE THIS EQUIPMENT.

IMPROPER WIRING COULD CAUSE DEATH, INJURY AND/OR EQUIP-

MENT DAMAGE. ONLY LICENSED/QUALIFIED ELECTRICIANS WHO ARE 

TRAINED IN THE INSTALLATION AND SERVICE OF ELECTRICAL SER-

VICES ARE TO INSTALL AND SERVICE THIS EQUIPMENT.

HAZARDOUS VOLTAGES ARE PRESENT INSIDE THE SPD DURING 

NORMAL OPERATION.

 

FOLLOW ALL SAFE WORK PRACTICES TO AVOID 

ELECTRICAL SHOCK.

 

  

WARNING

ARC FLASH DURING INSTALLATION COULD CAUSE INJURY. USE 

APPROPRIATE SAFETY PRECAUTIONS AND EQUIPMENT FOR ARC 

FLASH PROTECTION.

  

1.4 Catalog Numbering System

Each Eaton SPD Series unit has a name plate that identifies 

the parameters used for manufacture. These parameters are 

expressed in letters and numbers, to reflect the Series, kA 

Rating, Voltage Code, Feature Package, and Application as 
shown in Table 1.  

Table 1.  Catalog Numbering System

                         

SPD   250   480D   2   K

      

For example, a 480 volt Delta (3-wire plus Ground) for use in an 

NEMA 1 application requires an SPD model SPD 250480D2K, 

where:
SPD = SPD model,
250 = the kA rating (50 – 400 kA),
480D = the voltage, 
2  =  the  feature  package  (Basic,  Standard,  Standard  With  Surge               

Counter), and, 
K = the Application Suffix (such as NEMA 1 or NEMA 4 with 

internal disconnect).

 

These numbers appear as part of the product label attached to 

the front left side of the SPD. See Figure 1.

Figure 1. Product Label

kA Rating

Application

 

 

 Feature Package

Voltage Code

 

Series

Содержание SPD120480D3M

Страница 1: ...l Distribution Equipment Instruction Manual IM01005031E Effective November 2012 Rev 2 Table of Contents 1 0 Introduction 2 0 Installation 3 0 Operating Features 4 0 Troubleshooting 5 0 Specifications...

Страница 2: ...and are intended to be installed in applications with a degree of protection rated IP 20 1 3 Safety Precautions A licensed qualified electrician must complete all instructions in this manual in accord...

Страница 3: ...eck the facility grounding system All grounding bonding and earthing must meet the NEC and any other national state and local electrical codes 2 2 Installation Locations Eaton s SPD Series can be inst...

Страница 4: ...state and local electrical codes when mak ing these connections Figure 2 NEMA 1 With Flushmount Suffix L 4 IM01005031E Rev 2 Effective November 2012 Eaton SPD Series For Mounting External To Electrica...

Страница 5: ...K Figure 4 NEMA 4 4X Suffix N P 5 IM01005031E Rev 2 Effective November 2012 Eaton SPD Series For Mounting ExternalTo Electrical Distribution Equipment eaton corporation www eaton com NEMA 1 Suffix K...

Страница 6: ...v 2 Effective November 2012 Eaton SPD Series For Mounting External To Electrical Distribution Equipment eaton corporation www eaton com NEMA 1 With Disconnect Suffix M Figure 5 NEMA 4 4X With Disconne...

Страница 7: ...ting External to Electrical Distribution Equipment BLUE WHITE RED WHITE ORANGE WHITE COMMON NORMALLY OPEN NORMALLY CLOSED Figure 7 Sidemount Form C Wires Figure 8 Split Phase Units Figure 9 3 Phase De...

Страница 8: ...nt for each feature package Each display has both green and red light emitting diodes LEDs to indicate the status of the protection on each phase Green indicates the phase is fully protected Red indic...

Страница 9: ...the display 3 Remove the two phillips head screws that hold the display 4 Rotate the display to the desired position Be careful not to overstress the display ribbon cable 5 Place the display back onto...

Страница 10: ...Significant surge event Replace SPD Replace SPD with correct voltage model Check electrical system for TOV sources correct replace SPD Replace SPD One of the display Red LEDs is ON Audible Alarm is O...

Страница 11: ...nits 208Y 220Y 230L 240S 240D and 240H voltage codes 0 6W 400Y 480Y and 480D Basic voltage codes 1 7W 600Y and 600D voltage codes 2 1W Protection modes Single split phase L N L G N G L L Single phase...

Страница 12: ...colored LED to indicate Protection Status of the N G Mode on units with a Neutral Wire Audible alarm with Silence button Form C Relay Contact EMI RFI filtering Providing up to 50dB of Noise Attenuatio...

Страница 13: ...m determined by Eaton to be defec tive The giving of or failure to give any advice or recommenda tions by Eaton shall not constitute any warranty by or impose any liability upon Eaton The foregoing co...

Страница 14: ...nd conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser THERE ARE NO UNDERSTANDINGS AGREEMENTS WARRANTIES EXPRESSED OR IMPLIED INCLU...

Отзывы: